| Plan Review Notes For Permit 02110117 |
| Permit Number |
02110117 |
|
| Review Stop |
P |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2003-01-13 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | A) PREVIOUS PLAN REVIEW COMMENTS NOT | | | ADDRESSED. | | | 1) SHT D-1 ALL PLUMMBING, SANITARY/WATER | | | LINES CAPPED SHALL BE INSPECTED PRIOR TO | | | COVERING. | | | 2) SHT M/E-1 PLUMBING NOTES #1, CODE IN | | | EFFECT IS FBC-2001 PLUMBING NOT STANDARD | | | PLEASE CHANGE REFERENCE. | | | 3) SHT M/E-1 PLUMBING RISER SHALL RE- | | | FLECT THE FLOOR PLAN. THE LAUNDRY ROOM | | | IS TO THE LEFT OF THE KITCHEN, NOT BE- | | | TWEEN THE KITCHEN AND BATH RISERS. ALSO | | | THE LAUNDRY TRAY IS NOT SHOWN ON THE | | | RISER. A CLEANOUT IS REQUIRED ON RISER | | | ABOVE THE WASH MACHINE MINIMUM OF 4' | | | ABOVE FINISHED FLOOR. | | | 4) SHT M/E-1 PLUMBING RISER, ISLAND VENT | | | DOES NOT MEET CODE. (SUGGEST AN AIR AD- | | | MITTENCE VALVE) | | | 5) PER BLDG OFFICIAL, ONCE A PLAN COMES | | | IN FOR REVIEW WITH A RISER DIAGRAM, A | | | RISER DIAGRAM SHALL BE REQUIRED. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|