2003-03-24 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FHA-98 AMENDED DESIGN MANUAL
  
 1) SHT A-3 CARISSA MODEL, FLOOR PLAN
 SHOWS BATH #3 WITH A W/C, LAV, & SHOWER.
 SHT A-16 SANT. RISER DIAGRAM SHOWS W/C,
 LAV, & A BAR SINK. PLEASE CLAIRFY.
 2) SHT A-16 CARRISA MODEL, BEGONIA MODEL
 & DATURA MODEL, SANT DRAIN REQUIRED TO
 BE MINIMUM OF 3" UP TO WHERE THE TUB IS
 TAKEN OFF BRANCH DRAIN. TABLE 909.3 &
 SECTION 909.1 WET VENT. (SEE 2ND FLOOR
 MASTER BATH FOR ALAMANDA MODEL)
  
 REVIEW BY KEN STEVENS