2003-09-30 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 805 6716
 E-MAIL: [email protected]
  
 FBC = FLORIDA BUILDING CODE 2001
 FBC*= FLORIDA BUILD'G CODE (CITY AMEND)
  
 FOR CONSISTENCY, THE FOLLOWING COMMENTS
 ARE NUMBERED AS PER THE BUILDING PLAN
 REVIEW OF 6/3/03:
  
 3) THE NOTICE OF COMMENCEMENT SHALL BE
 RECORDED AT PALM BEACH COUNTY COURTHOUSE
 AND A COPY SUBMITTED TO THIS OFFICE
 BEFORE A PERMIT CAN BE ISSUED.BLANK
 FORMS ARE AVAILABLE FROM THIS OFFICE.
  
 4) IMPACT FEES. THE PLANS SHALL BE TAKEN
 TO PALM BEACH COUNTY BUILDING DEPARTMENT
 FOR IMPACT FEE ASSESSMENT. THEY SHALL BE
 STAMPED AT THAT OFFICE AND A COPY OF THE
 PAID RECEIPT SUBMITTED TO THE CITY OF
 WEST PALM BEACH DEPT OF CONSTRUCTION
 SERVICES BEFORE A PERMIT CAN BE ISSUED.
  
 6) FBC 13-103.1.1.1 AND 103.1.2SHEET 2
 OF THE SUBMITTED ENERGY CODE COMPLIANCE
 FORMS SHALL BE SIGNED BY THE OWNER (OR
 THE PROJECT ARCHITECT, OR OTHER
 AUTHORIZED AGENT DESIGNATED BY THE
 OWNER) TO CERTIFY COMPLIANCE WITH THE
 CODE.ALSO, ON SHEET 1, COMPLETE THE
 PROJECT DETAILS INCLUDING NAME OF OWNER,
 PROJECT ADDRESS (4884 N. HAVERHILL RD),
 ZIP (33417) AND PERMIT NUMBER (02102198)
  
 7) PRODUCT APPROVALS.THE PRODUCT
 APPROVAL SHEETS SHALL BE MARKED, AS
 APPROPRIATE TO IDENTIFY WHICH PRODUCT
 OPTIONS/MATERIALS/SIZES ARE TO BE USED,
 ALSO:
 (I) DRAWING SHEET 1 OF THE SUBMITTED PGT
 INDUSTRIES ALUMINUM FIXED WINDOW PRODUCT
 APPROVAL NOA# 01-0102.01 STATES THAT THE
 DESIGN PRESSURE RATING OF THE IMPACT
 WINDOWS, WITH HEAT STRENGTHENED
 LAMINATED GLASS, IS +60 PSF & -60 PSF.
 THIS IS EXCEEDED BY THE MAXIMUM NEGATIVE
 DESIGN PRESSURE (-76 PSF) STATED ON PLAN
 SHEETS A1-5.1 AND A1-5.2 (ELEVATIONS).
 SUBMIT A PRODUCT APPROVAL WITH THE
 APPROPRIATE DESIGN PRESSURE RATING.
 (J) SUBMIT A PRODUCT APPROVAL FOR THE
 GLAZED SLIDING DOORS TO THE GUARD HOUSE.
  
 --PROVISO--
 THE SUBMITTED ARCH ALUMINUM NARROW STILE
 DOOR PRODUCT APPROVAL NOA# 01-0910.09
 STATES THAT THESE DOORS ARE NOT IMPACT
 RESISTANT.SUBMIT A PRODUCT APPROVAL
 FOR HURRICANE MISSILE IMPACT PROTECTION
 SHUTTERS IF THESE DOORS ARE TO USED.
  
 --PROVISO--
 THE SUBMITTED ARCH ALUMINUM SERIES 4500
 STOREFRONT PRODUCT APPROVAL
 NOA# 00-1220.05 STATES THAT THIS SYSTEM
 IS NOT IMPACT RESISTANT.SUBMIT A
 PRODUCT APPROVAL FOR HURRICANE MISSILE
 IMPACT PROTECTION SHUTTERS IF THIS
 SYSTEM IS TO BE USED.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL INFO