2003-01-08 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 659 8096 EXT 8499
  
 FBC = FLORIDA BUILDING CODE 2001
 FBC*= FLORIDA BUILD'G CODE (CITY AMEND)
  
 1) FBC* 104.2.4A SIGNED AND SEALED
 SURVEY DRAWING IS REQUIRED.
  
 2) FL. ADMIN. CODE 61G1-16.003EACH
 ARCHITECTURAL PLAN SHEET SHALL BE SIGNED
 PERSONALLY, NOT SIGNATURE STAMPED.
  
 3) INFORMATIVE:
 A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 4) INFORMATIVE:
 IMPACT FEES MUST BE PAID TO PALM BEACH
 COUNTY, THE PLANS STAMPED BY THEM AND A
 COPY OF THE RECEIPT SUBMITTED TO THE
 CITY OF WEST PALM BEACH CONSTRUCTION
 SERVICES DEPARTMENT BEFORE A BUILDING
 PERMIT CAN BE ISSUED.
  
 5) FBC 11-4.1.2THE BUILDING SHALL BE
 SERVED BY AT LEAST ONE ACCESSIBLE ROUTE
 FROM THE ACCESSIBLE PARKING.
 ACCEPTABILITY OF THESE PLANS IS
 CONTINGENT UPON THE CIVIL/SITE PLANS,
 PERMIT# 02102208, BEING PERMITTED.
  
 6) FBC 13-103.0ENERGY CODE COMPLIANCE
 SHALL BE DEMONSTRATED BY SUBMITTAL OF
 APPROPRIATE CODE COMPLIANCE FORMS
  
 7) SUBMIT PRODUCT APPROVALS FOR THE
 ROOFING, EXTERIOR DOORS AND WINDOWS.
  
 8) FBC 1403.9ELEVATION SHEETS A1-5.1 &
 A1-5.2.4" VINYL SIDING IS SPECIFIED IN
 NOTE 2.RIGID VINYL SIDING IS LIMITED
 TO TYPE VI CONSTRUCTION.FROM TABLE 500
 THE AREA OF THIS BUILDING EXCEEDS THE
 ACCEPTANCE CRITERIA FOR TYPE VI
 CONSTRUCTION.
  
 9) FBC* TABLE 2306.1STRUCTURAL NOTES,
 SHEET STR-GN, PLYWOOD ROOF DECKING.THE
 PERIMETER ZONE AT THE GABLE ENDS SHALL
 HAVE NAILS SPACED AT 4"O.C. MAXIMUM, TO
 A DISTANCE OF 5 FEET (NOT 24") FROM THE
 EDGE OF THE ROOF.
  
 10) STRUCTURAL NOTES, SHEET STR-GN, WOOD
 TRUSS NOTE 6.IT IS NOTED THAT THE
 TRUSS DESIGN ENGINEER IS TO PROVIDE THE
 WIND UPLIFT REACTIONS.THE PERMIT
 CANNOT BE ISSUED UNTIL THE REACTIONS ARE
 SPECIFIED ON THE PLANS FOR CROSS
 REFERENCE AGAINST THE PROPOSED TRUSS
 ANCHORS AND STRAPS.
  
 11) FBC 11-4.9.4(2)SHEET A1-8.1, TYP.
 SIDE WALL RAILING DETAIL (ALSO SHEET
 A1-9.1 STAIR 109/209 SECTION).THE
 HANDRAIL SHALL EXTEND AT LEAST 12"
 HORIZONTALLY BEYOND THE TOP RISER, AND
 SHALL CONTINUE TO SLOPE PAST THE BOTTOM
 RISER FOR A DISTANCE EQUAL TO THE WIDTH
 OF ONE TREAD AND THEN A FURTHER 12"
 HORIZONTALLY AT THE BOTTOM.
  
 12) FBC 11-4.13.6MANEUVERING CLEARANCE
 AT DOORS.THE LEADING EDGE OF DOOR 202B
 SHOULD BE NO LESS THAN 18" AWAY FROM THE
 CORRIDOR WALL ON THE PULL SIDE OF THE
 DOOR.
  
 13) FBC 11-4.16.3SHEET A1-2.41, DETAIL
 5A AND SHEET A1-4.1, DETAIL 2A, 2B, 4A.
 THE HEIGHT OF THE W.C. SEAT SHOULD BE
 17" TO 19", NOT 1'-3".
  
 14) FBC 2405.2THE GLAZED PANEL AT HR
 RECEPTION IS WITHIN 24" OF DOOR 103.
 THIS IS A 'HAZARDOUS LOCATION' AND IS
 REQUIRED TO BE SAFETY GLASS SATISFYING
 THE REQUIREMENTS OF THE CONSUMER PRODUCT
 SAFETY COMMISSION 16, CODE OF FEDERAL
 REGULATIONS, PART 1201 (CPSC 16-CFR,
 PART 1201).SUBMIT DETAILS TO
 DEMONSTRATE COMPLIANCE.
  
 15) IF NEW PLAN SHEETS ARE REQUIRED, IN
 ORDER TO ADDRESS THE ABOVE COMMENTS, THE
 OLD SHEETS SHALL BE REMOVED AND THE NEW
 SHEETS INSERTED.ONE COPY OF EACH OLD
 SHEET SHALL BE INCLUDED WITH THE
 RESUBMITTAL FOR COMPARISON OF REVISIONS.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL INFO
 IF YOU HAVE ANY QUESTIONS PLEASE CALL:
 ROBERT BROWN(561) 659 8096 EXT 8499