| 2002-11-26 00:00:00 | BUILDING REVIEW APPROVED WITH PROVISO: | | | 1-ARCHITECT TO REVISE DETAIL FOR ONE HR | | | FIRE RATED WALL ASSEMBLY AT ZERO LOT | | | LINE. TABLE REFERENCED ON DETAIL 11/S3 | | | IS FOR CONCRETE WALL ASSEMBLIES, NOT | | | FOR WOOD. SEE SECTION 709.6 FOR WOOD | | | ASSEMBLIES AND PROVIDE COMPLETE | | | ASSEMBLY DETAIL TAKING INTO CONSIDERA- | | | TION INTERIOR AND EXTERIOR EXPOSURE TO | | | THE FIRE AS REQUIRED BY TABLE 600 FBC. | | | 2-ARCHITECT TO REVISE THE DIAPHRAGM | | | SCHEDULE TO MATCH ENGINEERING SPECS. | | | 3-PROVIDE COMPLETE INFORMATION FOR STORM | | | SHUTTERS UNDER A SEPARATE PERMIT. | | | 4-PROVIDE COMPLETE INFORMATION ON DETAIL | | | 41/S1. SPECIFY ANCHOR SIZE TO BE USED. | | | SEC. 104.2.1.2 CITY AMENDMENTS TO FBC. |
|