| Plan Review Notes For Permit 02101887 |
| Permit Number |
02101887 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2003-01-15 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 02101887 | | | ADD: 3177 SANTA MARGARITA RD | | | CONT: DOUBLE "R" CONST | | | TEL: (954)444-7093 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | 1)BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 2) PROVIDE NOC RECORDED WITH THE CLERK | | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 3) FL BLD CODE 1804.2.2 QUESTIONABLE | | | SOILS, WHERE THE BEARING CAPACITY IS | | | NOT DEFINETLY KNOWN OR IS IN QUESTION. | | | | | | CONTRACTOR IS CONTINUING AT OWN RISK!!! | | | THE SOILS REPORT SUBMITTED TO THIS | | | OFFICE "A PRELIMINARY GEOTECHNICAL EVAL- | | | UATION, SECTION 7. THE REPORT INDICATES | | | THAT IN SEC. 4.3 BUILDING FOUNDATION : | | | ALL FINAL DESIGNS SHOULD BE BASED ON A | | | MORE COMPREHENSIVIVE STUDY ONCE THE | | | BUILDING LOCATIONS AND STRUCTURAL LOADS | | | ARE FINALIZED. | | | BUILDING PLAN REVIEW | | | JIM WITMER |
|