| 2003-09-08 00:00:00 | REVISION TO CHANGE FROM TWO STORY GARAGE | | | TO ONE STORY IS DENIED. | | | | | | 1) THE ORIGINAL PLANS ARE SIGNED AND | | | SEALED BY AN ENGINEER (JOHN HOLT). | | | THEREFORE, THE REVISED PLANS ARE | | | REQUIRED TO BE SIGNED AND SEALED BY THE | | | ENGINEER OF RECORD. THE ENGINEER'S TITLE | | | BLOCK IS REQUIRED TO BE ON THE PLANS. | | | | | | 2)PROVIDE (2) CURRENT AND COMPLETE | | | COPIES OF SBCCI OR METRO-DADE PRODUCT | | | APPROVALS FOR: | | | - 10' WIDE OVERHEAD GARAGE DOORS (WERE | | | CHANGED FROM 8' WIDE DOORS) | | | - ROOFING MATERIAL (WAS CHANGED BY | | | REVISION) | | | | | | 3) THE WALL SECTION SPECIFIES AN 18" | | | DEEP FOOTER AND THE FOUNDATION PLAN | | | SPECIFIES A 16" THICK FOOTER. PLEASE | | | CORRECT. THE FBC REQUIRES THE BOTTOM OF | | | THE FOOTER TO BE 12" BELOW FINAL GRADE. | | | | | | IF YOU HAVE QUESTIONS, PLEASE CALL. | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|