| Plan Review Notes For Permit 02101141 |
| Permit Number |
02101141 |
|
| Review Stop |
R |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2003-01-07 00:00:00 | BUILDING DENIED | | | | | | 1) INDICATE THE NEGATIVE AND POSITIVE | | | DESIGN WINDLOAD PRESSURES FOR ALL | | | EXTERIOR OPENINGS. | | | | | | 2) REVISE THE TYPICAL WALL SECTION ON A5 | | | TO INDICATE THE FINISH FLOOR ELEVATION | | | TO BE A MINIMUM OF 4" ABOVE FINAL GRADE | | | AS REQUIRED BY CITY OF WPB AMENDMENTS TO | | | FBC 1804.1.7. THE 6" MINIMUM INDICATED | | | WILL NOT PROVIDE THE MINIMUM 12" BELOW | | | GRADE REQUIRED TO THE BOTTOM OF THE | | | FOOTINGS WITH 16" DEEP FOOTINGS. | | | | | | 3) THE REAR ELEVATION ON A-4 AND SECTION | | | A-A ON A-5 STILL SHOW THE BUTT GLASS | | | WINDOW, WHICH WAS CHANGED ON THE FLOOR | | | PLAN. | | | | | | 4) SPECIFY THE MINIMUM REQUIRED EMBED | | | DEPTH FOR THE 1/2" ANCHOR BOLTS USED TO | | | ATTACH THE GARAGE DOOR BUCKS IN THE | | | DETAIL ON A5. | | | | | | 5)PROVIDE (2) CURRENT AND COMPLETE | | | COPIES OF SBCCI OR METRO-DADE PRODUCT | | | APPROVALS FOR: | | | - OUTSWING DOUBLE DOOR WITHOUT SIDELITES | | | - SINGLE HUNG WINDOWS | | | - SINGLE OUTSWING FRENCH DOORS | | | - FIXED GLASS WINDOWS (ARCHED, OVAL, | | | SQUARE, ETC.) | | | - SLIDING GLASS DOORS | | | - STRUCTURAL MULLIONS | | | - HORIZONTAL SLIDING WINDOWS | | | NOTE: PRODUCT APPROVALS MUST MATCH THOSE | | | SHOWN ON PLANS. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)659-8096 EXT.8202 |
|