Plan Review Notes
Plan Review Notes For Permit 02101140
Permit Number 02101140
Review Stop R
Sequence Number 1
Notes
Date Text
2002-11-22 00:00:00BUILDING DENIED
  
 1) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 2) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 3)FL. BLD CODE 1606.1.7 THE FOLLOWING
 INFORMATION RELATED TO WIND SHALL BE
 SHOWN ON THE CONSTRUCTION DRAWINGS,
 1)- BASIC WIND SPEED, MPH
 2)- WIND IMPORTANCE FACTOR, & BUILDING
 CATEGORY
 3)- WIND EXPOSURE
 4)- INTERNAL PRESSURE COEFFICIENT,
 5)- COMPONENTS & CLADDING, THE DESIGN
 WIND PRESSURES IN TERMS OF PSF.
 INDICATE THE INTERNAL PRESSURE
 COEFFICIENT ON THE PLANS (+ OR - .18 FOR
 ENCLOSED STRUCTURES).
  
 4) REVISE NOTE 11 ON C1, HURRICANE
 SHUTTERS ARE REQUIRED IN THE CITY OF WPB
 AND IT IS NOT LOCATED IN A HVHZ.
  
 5) REVISE FRAMING NOTE 15 ON C1, ASTM C
 1063 REQUIRES 3/8" RIB METAL LATH TO BE
 FASTENED AT EACH RIB (4").
  
 6) THE LINES DESIGNATING THE FOOTING ARE
 NOT INDICATED FOR ONE OF THE F6 FOOTINGS
 AT THE COVERED ENTRY.
  
 7) THE FOOTING SCHEDULE ON A1 REFERS TO
 DETAIL 8 FOR THE F4 PAD AT THE WOOD
 POST. DETAIL 8 IS FOR A STEEL COLUMN.
  
 8) SPECIFY ACCESS TO ATTIC SPACE AS
 REQUIRED BY FBC 2309.6.
  
 9) SPECIFY SAFETY GLASS AT THE WINDOWS
 AT THE TUB IN THE LADIES GRANDE SUITE &
 IN HIS BATH AS REQUIRED BY FBC 2405.2.
  
 10) REVISE THE TYPICAL WALL SECTION ON
 A4 FROM 6" TO 4" MINIMUM ABOVE GRADE TO
 FINISH FLOOR. SEE CITY AMENDMENTS
 1804.1.7 AND FBC 1804.1.3.
  
 11) SPECIFY THE REQUIRED EMBEDMENT DEPTH
 FOR THE 1/2" ANCHOR BOLTS AT THE GARAGE
 DOOR BUCKS ON A4.
  
 12) REVISE DETAIL 13 ON A5 TO SHOW THE
 HANGER ON A 45 DEGREE ANGLE.
  
 13) THE 14 ON A5 TAG ABOVE THE LIVING
 ROOM WINDOWS IS IN THE WRONG LOCATION.
  
 14) DETAIL 5 ON A5 IS MISLABELED AS 5 ON
 A6.
  
 15) SPECIFY THE HANGERS FOR THE 38" DEEP
 GIRDERS ON EACH SIDE OF THE COVERED
 ENTRY.
  
 16) AN L-9 IS SPECIFIED ON SHEET A5
 ABOVE THE LIVING ROOM WINDOW, HOWEVER,
 IT IS NOT LISTED IN THE TIE-BEAM
 SCHEDULE.
  
 17) THE LINTEL ABOVE THE FRONT DOOR IS
 INDICATED ON A-5 AS 8"X16",BUT ON THE
 ELEVATION IT APPEARS TO BE 8"X8". PLEASE
 CLARIFY.
  
 18) ON SHEET A6 THE WRONG DETAILS ARE
 SPECIFIED IN THREE PLACES. SEE THE RED
 LINES ON SHEET A6 AND CORRECT.
  
 19) THE FLOOD ZONE INFORMATION GIVEN ON
 THE SURVEY IS NOT CORRECT. PLEASE
 REVISE.
  
 20) THE CONDITIONED FLOOR AREA LISTED ON
 THE PLANS DIFFERS FROM THE A/C AREA ON
 THE PLANS. PLEASE CORRECT.
  
 21) THE OWNER/AGENT IS REQUIRED TO SIGN
 AND DATE THE ENERGY CALCULATION FORM.
  
 22) INDICATE ON THE PLANS THAT THE WALL
 ADJACENT TO THE GARAGE IS INSULATED AND
 THE DOOR IS TO BE INSULATED OR SOLID
 CORE WOOD PER CHAPTER 13 OF THE FBC.
  
 23) INDICATE ON THE PLANS THE ROOF
 SHEATHING NAILING REQUIREMENTS AND ROOF
 ZONES AS REQUIRED BY THE CITY OF WPB
 AMENDMENTS TO FBC TABLE 2306.1.
  
 24) PROVIDE (2) CURRENT AND COMPLETE
 COPIES OF SBCCI OR METRO-DADE PRODUCT
 APPROVALS FOR:
 - OUTSWING DOUBLE DOOR WITHOUT SIDELITES
 - SINGLE OUTSWING FRENCH DOOR
 - DOOR AT MECHANICAL ROOM
 - OVERHEAD GARAGE DOOR(INFORMATION THAT
 WAS SUBMITTED IS NOT ACCEPTABLE)
  
 25) IF THE NORANDEX PRODUCTS DO NOT HAVE
 SBCCI OR METRO-DADE PRODUCT APPROVALS,
 SITE SPECIFIC ENGINEERING IS REQUIRED.
 THE SITE SPECIFIC PRODUCT APPROVAL FORMS
 ARE REQUIRED TO BE SIGNED, SEALED AND
 DATED BY THE ENGINEER CERTIFYING THE
 PRODUCT AND THE DESIGNER OF RECORD MUST
 SIGN, SEAL AND DATE THE FORM INDICATING
 THAT HE HAS REVIEWED THE PRODUCT AND IS
 APPROVING ITS USE IN THE STRUCTURE. THE
 LOCATION OF THE STRUCTURE IS TO BE
 SPECIFIED ON THE FORM. THE SPECIFIC
 PRODUCTS BEING INSTALLED ARE TO BE
 LISTED ON THE FORMS AND SHOWN IN THE
 DRAWINGS, OR AN EGINEERED ANALYSIS FOR A
 DIFFERENT SIZE OR SHAPE BASED ON THE
 TESTED PRODUCT WILL BE REQUIRED.
  
 26) PROVIDE AN INSTALLATION SCHEDULE AND
 KEY PLAN FOR THE HURRICANE PANELS.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202