| Notes |
| Date |
Text |
| 2002-10-30 00:00:00 | THE PROPOSED ELEVATED SEATING AREAS ARE | | | REQUIRED TO BE HANDICAP ACCESSIBLE BY | | | FBC 11-5.4PLEASE REVISE AS NECESSARY. | | | | | | PROVIDE AN ENGINEERING ANALYSIS | | | DEMONSTRATING THE EXISTING STRUCTURE | | | CAN SUPPORT THE ADDED DEAD LOAD OF THE | | | SEVERAL SIX INCH CONCRETE AREAS | | | PROPOSED TO BE CONSTRUCTED. | | | | | | PROVIDE THE DESIGN WIND PRESSURES FOR | | | THE PROPOSED EXTERIOR STORE FRONT | | | SYSTEM.SEE FBC 1606.1.7 #5 AND THE | | | METHOD OF HURRICANE MISSILE RESISTANCE. | | | FBC 1606.1.4. | | | | | | IF TEST AND NOTICE OF ACCEPTANCE | | | REPORTS FOR THE STORE FRONT SYSTEM | | | ARE NOT INCLUDED WITH THE PERMIT | | | APPLICATION A SEPARATE PERMIT, PLANS | | | AND FEE WILL BE REQUIRED FOR THEIR | | | INSTALLATION. |
|