| 2003-07-14 00:00:00 | PROVISO: | | | | | | AIR HANDLING UNIT #2 - | | | AIR HANDLING UNITS INSTALLED IN ATTICS | | | SHALL COMPLY WITH THE FOLLOWING AS PER | | | 2001 FBC CHAPTER 13 SUB-CHAPTER 6 SEC | | | 610.1.ABC.3.5.2 & 2001 FBC(M) 306.3: | | | | | | 1. THE SERVICE PANEL OF THE EQUIPMENT IS | | | LOCATED WITHIN 6 FEET OF AN ATTIC ACCESS | | | | | | 2. A DEVICE IS INSTALLED TO ALERT THE | | | OWNER OR SHUT THE UNIT DOWN WHEN THE | | | CONDENSATION DRAIN IS WORKING PROPERLY. | | | | | | 3. THE ATTIC ACCESS OPENING SHALL BE | | | SUFFICIENT SIZE TO REPLACE THE AHU, NOT | | | LESS THAN 20" X 30". | | | | | | 4. A NOTICE IS POSTED ON THE ELECTRIC | | | SERVICE PANEL INDICATING TO THE HOME | | | OWNER THAT THE AHU IS LOCATED IN THE | | | ATTIC. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|