| Plan Review Notes For Permit 02100090 |
| Permit Number |
02100090 |
|
| Review Stop |
R |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2002-12-13 00:00:00 | TRUSSES DENIED | | | | | | 1) THE TRUSS DRAWINGS ARE DESIGNED FOR | | | A 110 MPH WINDLOAD THE CITY OF WPB IS | | | LOCATED IN A 140 MPH WIND ZONE. SEE FBC | | | 1606 AND ASCE 7-98. | | | | | | 2) THE DESIGNER OF RECORD FOR THE | | | STRUCTURE IS REQUIRED TO REVIEW AND | | | APPROVE THE TRUSS DRAWINGS AND LAYOUT. | | | | | | 3) THE TRUSS ENGINEER'S WET SIGNATURE IS | | | REQUIRED ON ALL DOCUMENTS SUBMITTED FOR | | | PUBLIC RECORD. SEE 61G15-23.002 FAC. | | | A SIGNATURE STAMP IS NOT ACCEPTABLE. | | | | | | 4) THE TRUSS PACKAGES FOR ONE AND TWO | | | FAMILY DWELLINGS ARE NOT REQUIRED TO BE | | | SUBMITTED FOR PLAN REVIEW. THEY ARE | | | REQUIRED TO BE GIVEN TO THE BUILDING | | | INSPECTOR TO REVIEW AT TIME OF TRUSS | | | INSPECTION AND HE WILL BRING IN THE | | | SIGNED AND SEALED DRAWINGS TO BE FILED | | | WITH THE APPROVED PLANS FOR PUBLIC | | | RECORD. |
|