| Date |
Text |
| 2003-01-15 00:00:00 | BUILDING DENIED |
| | |
| | 1) IMPACT FEES MUST BE PAID TO PALM |
| | BEACH COUNTY, PLANS STAMPED BY THEM AND |
| | COPY OF RECEIPT SUBMITTED TO CITY OF |
| | WEST PALM BEACH BUILDING DEPARTMENT, |
| | BEFORE A BUILDING PERMIT CAN BE ISSUED. |
| | |
| | 2) A RECORDED COPY OF THE NOTICE OF |
| | COMMENCEMENT MUST BE SUBMITTED BEFORE A |
| | PERMIT CAN BE ISSUED. |
| | |
| | 3) PROVIDE A SOIL TEST REPORT PRIOR TO |
| | POURING THE FOUNDATION PER L.HATTEN. |
| | |
| | 4) THE SURVEY SUBMITTED DOES NOT MATCH |
| | THE FOOTPRINT OF THE STRUCTURE SHOWN ON |
| | THE PLANS. THE STRUCTURES FOOTPRINT ON |
| | THE LANDSCAPE PLAN DOES NOT CORRESPOND |
| | WITH THE REST OF THE PLANS. THE COVERED |
| | ENTRY AND COVERED PATIOS DIFFER. PLEASE |
| | CORRECT. |
| | |
| | 5) PLEASE REVISE THE FASTENING |
| | REQUIREMENTS FOR THE HORIZONTAL WIRE |
| | LATH ON A2. ASTM C 1063 REQUIRES THE |
| | FASTENERS TO PENETRATE 1-3/4" INTO |
| | HORIZONTAL WOOD FRAMING MEMBERS. THE |
| | FASTENER SPACING FOR 3/8" RIB LATH IS |
| | AT EVERY RIB (4"O.C.) |
| | |
| | 6) THE 50"X60" FIXED GLASS WINDOW |
| | BETWEEN THE 25SH WINDOWS AT THE MASTER |
| | BEDROOM REQUIRES A DESIGN WINDLOAD OF |
| | +47.4 AND - 59.9 PSF. THE PRODUCT |
| | APPROVAL SUBMITTED HAS A + OR - 42.6 PSF |
| | DESIGN WINDLOAD FOR THIS SIZE WINDOW, |
| | WHICH DOES NOT MEET THE REQUIRED LOADS. |
| | |
| | D) THE PRODUCT APPROVAL FOR THE FOUR |
| | PANEL SLIDING GLASS DOOR DOES NOT MEET |
| | THE REQUIRED WINDLOAD PRESSURES LISTED |
| | ON THE PLANS. |
| | |
| | 8) THE SITE SPECIFIC PRODUCT APPROVAL |
| | FOR THE DOUBLE OUTSWING DOORS IS |
| | REQUIRED TO BE SIGNED, SEALED AND DATED |
| | BY THE DESIGNER OF RECORD FOR THE |
| | STRUCTURE. |
| | |
| | 9) SPECIFY THE EMBEDMENT DEPTH OF THE |
| | 3/4" DIAMETER WEDGE ANCHORS SPECIFIED |
| | FOR THE USC AND NFM CONNECTORS ON A8. |
| | |
| | 10) SAFETY GLASS IS REQUIRED IN THE |
| | WINDOW AT THE TUB IN BATH #2 AND IN THE |
| | WINDOW AT THE SHOWER IN THE MASTER BATH. |
| | PLEASE NOTE ON PLANS. |
| | |
| | ROBERT MCDOUGAL |
| | BLDG. PLAN REVIEW |
| | (561)659-8096 EXT.8202 |