| Plan Review Notes For Permit 02091769 |
| Permit Number |
02091769 |
|
| Review Stop |
B |
| Sequence Number |
4 |
|
| Notes |
| Date |
Text |
| 2003-07-10 00:00:00 | BUILDING PLAN REVIEW | | | ******PROVISO******* | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | --PROVISO-- | | | FBC 1005.4BEDROOMS #2 AND #3 ARE SHOWN | | | AS HAVING WINDOWS WITH SUFFICIENT HEIGHT | | | AND WIDTH FOR EGRESS. ALSO, THE BEDROOMS | | | SHALL EACH HAVE AT LEAST ONE OF THOSE | | | WINDOWS WITH A MINIMIUM NET CLEAR | | | OPENING OF 5.7 SQ FT. | | | | | | --PROVISO-- | | | FBC 1608.2.2.1IN ADDITION TO THE | | | STRENGTH REQUIREMENT STATED ON SHEET | | | S204/SK3, A 200 POUND POINT LOAD SHALL | | | BE RESISTED WHEN APPLIED (AS A SEPARATE | | | LOAD) IN ANY DIRECTION AT THE TOP OF THE | | | GUARDRAIL. | | | | | | --PROVISO-- | | | THE SUBMITTED ENERGY CODE COMPLIANCE | | | FORM INCORRECTLY STATES THE CONDITIONED | | | FLOOR AREA OF THE WHOLE HOUSE AS | | | 1147 SQ FT.SUBMIT TWO COPIES OF FORMS | | | WITH THE CORRECT AREA (3647 SQ FT). |
|