| 2002-11-05 00:00:00 | BUILDING PLAN REVIEW |
| | *******DENIED******* |
| | ROBERT BROWN(561) 659 8096 EXT 8499 |
| | |
| | FBC = FLORIDA BUILDING CODE 2001 |
| | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) |
| | |
| | 1) IMPACT FEES MUST BE PAID TO PALM |
| | BEACH COUNTY, PLANS STAMPED BY THEM AND |
| | COPY OF RECEIPT SUBMITTED TO CITY OF |
| | WEST PALM BEACH BUILDING DEPARTMENT, |
| | BEFORE A BUILDING PERMIT CAN BE ISSUED. |
| | |
| | 2) FBC* 104.2.1.2THE CHIMNEY IS SHOWN |
| | ON EACH OF THE EXISTING ELEVATIONS BUT |
| | IT IS OMITTED FROM THE PROPOSED |
| | ELEVATIONS.THERE ARE NO NOTES STATING |
| | THAT THE CHIMNEY IS TO BE REMOVED. |
| | CLARIFY/AMEND THE PLANS AS APPROPRIATE |
| | TO FULLY DESCRIBE THE SCOPE OF WORK. |
| | IS THE CHIMNEY TO BE REMOVED? |
| | |
| | 3) FBC 13-103.0ENERGY CODE COMPLIANCE |
| | SHALL BE DEMONSTRATED BY SUBMITTAL OF |
| | APPROPRIATE CODE COMPLIANCE FORMS (FORM |
| | 600C-01 SOUTH) |
| | |
| | 4) SUBMIT PRODUCT APPROVALS FOR THE NEW |
| | CEMENT TILE ROOFING, NEW AND REPLACEMENT |
| | WINDOWS, AND THE NEW GLAZED EXTERIOR |
| | DOORS.THE SPECIFICATION OF IMPACT |
| | RESISTANT GLAZING FOR BOTH NEW WINDOWS |
| | AND THE REPLACEMENT OF EXISTING WINDOWS |
| | IS NOTED. |
| | |
| | 5) FBC 1606.1.7WIND LOAD DESIGN |
| | INFORMATION.THE INFORMATION SHOWN ON |
| | THE PLANS IS NOTED, BUT FOR DESIGN OF |
| | EXTERIOR COMPONENTS AND CLADDING THE |
| | ROOF PRESSURES EXTRACTED FROM FBC TABLE |
| | 1606.2B ARE FOR A ROOF ANGLE OF 30 TO 45 |
| | DEGREES WHICH IS NOT CORRECT.AS THE |
| | ANGLE OF THE PROPOSED ROOF IS BETWEEN |
| | 10 AND 30 DEGREES, IT WILL BE SUBJECTED |
| | TO GREATER NEGATIVE WIND PRESSURES IN |
| | ZONES 2 AND 3.AMEND THE EXTRACTS ON |
| | BOTH SHEET S-203 AND SHEET S-701, AND |
| | REVIEW THE DESIGN ACCORDINGLY. |
| | |
| | 6) FBC 1606.2.3SHEET S-701.THE EDGE |
| | STRIP AND END ZONE DIAGRAM EXTRACTS FROM |
| | FBC FIGURE 1606.2(C) FOR COMPONENT AND |
| | CLADDING WIND LOAD ARE INCORRECT. |
| | ZONE 5 IS NOT SHOWN ON THE BUILDING |
| | ELEVATION, AND THE ZONES FOR HIPPED |
| | ROOFS HAVE BEEN INCORRECTLY LABELLED. |
| | AMEND THE PLANS. |
| | |
| | 7) ANCHORS AND STRAPS.SHEETS S-202 AND |
| | S-203 DO NOT STATE THE UPLIFT AT THE |
| | TRUSS SUPPORTS AND DO NOT SPECIFY ANCHOR |
| | REFERENCES AT FLOOR FRAMING OR ROOF |
| | TRUSS SUPPORT LEVELS.ADD THE REQUIRED |
| | INFORMATION TO THE PLANS. |
| | |
| | 8) WALL SECTION THROUGH LIBRARY.SHEET |
| | A-702, SECTION D SPECIFIES 'LSC18 STRAP' |
| | AT THE CABANA ROOM TRUSS SUPPORT. |
| | UNLIKE THE ANCHORS SPECIFIED ELSEWHERE |
| | ON THE PLANS, THIS IS NOT A SIMPSON |
| | REFERENCE.CLARIFY/AMEND THE REFERENCE |
| | AS APPROPRIATE. |
| | |
| | 9) FBC* TABLE 2306.1THE ROOF SHEATHING |
| | FASTENER TYPE AND SPACING SHALL ADDED TO |
| | THE PLANS TO DEMONSTRATE COMPLIANCE WITH |
| | THIS CITY OF WPB AMENDMENT TO FBC 2001. |
| | |
| | 10) FBC 2309.6ACCESS TO ATTIC SPACE. |
| | AMEND THE PLANS TO SHOW THE PROVISION OF |
| | AN OPENING, NOT LESS THAN 20"X 36", FOR |
| | EACH ATTIC SPACE THAT HAS A CLEAR HEIGHT |
| | OF 24" OR GREATER. |
| | |
| | 11) FBC 2405.2THE GLAZING IN THE NEW |
| | ALUMINUM EXTERIOR DOORS IS IN A |
| | 'HAZARDOUS LOCATION' AND IS REQUIRED TO |
| | BE SAFETY GLASS SATISFYING THE |
| | REQUIREMENTS OF THE CONSUMER PRODUCT |
| | SAFETY COMMISSION 16, CODE OF FEDERAL |
| | REGULATIONS, PART 1201 (CPSC 16-CFR, |
| | PART 1201).SUBMIT DETAILS TO |
| | DEMONSTRATE COMPLIANCE. |
| | |
| | 12) IF NEW PLAN SHEETS ARE REQUIRED, IN |
| | ORDER TO ADDRESS THE ABOVE COMMENTS, THE |
| | OLD SHEETS SHALL BE REMOVED AND THE NEW |
| | SHEETS INSERTED.ONE COPY OF EACH OLD |
| | SHEET SHALL BE INCLUDED WITH THE |
| | RESUBMITTAL FOR COMPARISON OF REVISIONS. |
| | |
| | **QUOTE PERMIT# ON ALL CORRESPONDENCE** |
| | |
| | END OF REVIEW COMMENTS |
| | THE CODE REFERENCES GIVE ADDITIONAL INFO |
| | IF YOU HAVE ANY QUESTIONS PLEASE CALL: |
| | ROBERT BROWN(561) 659 8096 EXT 8499 |