| Plan Review Notes For Permit 02091711 |
| Permit Number |
02091711 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2002-10-09 00:00:00 | DENIED | | | REFERENCE: FBC-2001 424.2 SWIMMING POOLS | | | | | | A) PLEASE ADJUST YOUR NOTES, DETAILS, OR | | | SUBMITTALS TO REFLECT THE FOLLOWING IN- | | | FORMATION REQUIRED FOR PLAN REVIEW | | | 1) FBC-200142412.7.1 POOL CIRCULATING | | | PUMPS SHALL BE EQUIPPED ON THE INLET | | | SIDE WITH AN APPROVED TYPE HAIR AND LINT | | | STRAINER WHEN USED WITH A PRESSURE FIL- | | | TER. (DETAIL) | | | 2) FBC-2001 424.2.14.1 SWIMMING POOL | | | WATER HEATERS SHALL BEAR THE LABEL OF A | | | RECOGNIZED TESTING AGENCY. MANUFACTURE | | | SHEETS REQUIRED. (SUBMITTAL) | | | 3) FBC-2001 424.2.14.2 WATER RETENTION, | | | PROVIDE A POSITIVE MEANS OF RETAINING | | | WATER IN THE HEATER WHEN PUMP IS SHUT | | | OFF. (MANUFACTURE CUT SHEETS SUBMITTAL) | | | 4) FBC-2001 SECTION 13-612.1.ABC.2.3.3 | | | OF THE ENERGY CODE, TIME CLOCKS REQUIRED | | | ON PRIVATE POOLS. PLEASE SHOW ON ELECT. | | | DIAGRAM. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|