| 2002-09-30 00:00:00 | FAILED: |
| | 1. A SEPARATE PERMIT APPLICATION AND |
| | FEES FOR CIVIL SITE AND UNDERGROUND |
| | UTILITIES WILL BE REQUIRED. |
| | 2. PLEASE NOTE THAT ALL DRIVEWAY |
| | APPROACHES MUST BE CONSTRUCTED PER CITY |
| | OF WEST PALM BEACH STANDARD AND REQUIRE- |
| | MENTS. |
| | 3. PLEASE SHOW WATER AND SEWER |
| | CONNECTIONS FOR THE PROPOSED BUILDING, |
| | A BACKFLOW PREVENTER ANDCLEAN OUTS ON |
| | SEWER LATERAL WILL BE REQUIRED. |
| | 4. ALL PARKING STALLS MUST BE STRIPED, |
| | USING DOUBLE 4", PER CITY OF WEST PALM |
| | BEACH REQUIREMENTS. |
| | 5. PLEASE VERIFY THE STORM WATER CALC. |
| | AND THE ELEVATIONS AS SHOWN ON SHEET 1 |
| | OF 2 AND COMPARE WITH DETAILS ON SHEET |
| | 2 OF 2.ALSO VERIFY THE CONTROL ELEV. |
| | AND INVERTS ON ENTIRE PREFORATED PIPE. |
| | 6. A GARBAGE ENCLOSURE THAT COMPLIES |
| | WITH CITY REQUIREMENT SHOULD BE PROVIDED |
| | IF CITY PICK-UP. |
| | 7. CITY OF WPB' STANDARDS AND DETAILS |
| | MAY BE OBTAINED FROM PUBLIC UTILITIES |
| | 659-8040 EXT. 2306, MANNY GONZALEZ. |
| | 8. SEVICE AVAILABILITIES AND LOCATIONS |
| | FOR BACKFLOW PREVENTERS,METERS SHOULD BE |
| | COORDINATED WITH PUBLIC UTILITIES, |
| | 659-8040 EXT. 2306 MANNY GONZALEZ. |
| | IF ANY QUESTIONS PLEASE CONTACT 659-8096 |
| | EXT. 8492 MOHAMMAD R. AMINI |