| Date |
Text |
| 2002-10-12 00:00:00 | DENIED |
| | REFERENCE: FBC-2001 CHAPTER 11 |
| | FBC-2001 PLUMBING |
| | FBC-2001 |
| | |
| | 1) SHT CIVIL 6 0F 9 OIL/WATER SEPARATOR |
| | DETAIL, 2 WAY CLEAN OUTS ARE REQUIRED. |
| | 2) FOR OIL/WATER SEPARATOR SIZE CONTACT |
| | RODNEY COMPO, ENVIRONMENTAL COMPLIANCE |
| | MANAGER, (561) 837-4074. WASTE ORD. # |
| | 2938-96 |
| | 3) SHT LP-1 SEPARATE IRRIGATION PERMIT |
| | IS REQUIRED. |
| | 4) SHT A-1 MINIMUM FACILITIES CALLS FOR |
| | 3 DRINKING FOUNTAINS. 2 HI/LOW DRINKING |
| | FOUNTAINS ARE SHOWN WHICH COUNT AS 2. |
| | SEE SECTION 410.1 A WATER COOLER CAN BE |
| | USED AS A THIRD DRINKING FOUNTAIN. IF |
| | USED IT SHALL COMPLY WITH ARI-1010. |
| | PLEASE PROVIDE MANUFACTURE CUT SHEETS. |
| | 5) SHT A-1.3 DETAIL #7 LIFT PLATFORM PIT |
| | SHOWS A DRAIN, BUT NO PIPING IS INDICAT- |
| | ED OR SHOWN. PLEASE CLAIRFY. |
| | 6) SHT A-2 PLEASE PROVIDE CALCULATIONS |
| | FOR PRIMARY AND SECONDARY ROOF DRAINS. |
| | SHOW TOTAL SQUARE FOOTAGE OF ROOF AREA |
| | INCLUDING 1/2 AREA OF ALL VERTICAL WALLS |
| | SHOW SQUARE FOOTAGE FOR EACH ROOF DRAIN. |
| | SHOW LOCATION AND SIZE FOR SECONDARY |
| | ROOF DRAINS. |
| | 7) SHT A-8 FINISH SCHEDULE. THE WALLS OF |
| | ALL PUBLIC RESTROOMS SHALL BE LINED WITH |
| | A NON ABSORBENT MATERIAL TO A HEIGHT OF |
| | 4 FEET. SEC 1204.2 - PLEASE INDICATE THE |
| | PAINT TYPE FOR WALLS. |
| | 8) SHT A-9 DETAIL #7 WATER CLOSET SHALL |
| | BE SET 1'6" OFF WALL TO CENTER, NOT 1'4" |
| | AS SHOWN. LAV SHALL BE SET 34" TO FLOOD |
| | RIM LEVEL. |
| | 9) SHT A-9 DETAIL #14 W/C TO BE SET 1'6" |
| | TO CENTER OFF WALL NOT 1'4" AS SHOWN. |
| | 10) SHT A-10 DETAIL #16 SHOW DETAIL FOR |
| | BENCH PER 11-4.35.4 |
| | 11) SHT M-4 PLUMBING NOTES: NUMBERING |
| | SECQUENCE NOT CONSISTANT. #'S 10-11-12 |
| | REPETE. SECOND #10 REFERS TO AIR CHAMB- |
| | ERS WHICH ARE NOT APPROVED. PLEASE DE- |
| | LETE REFERENCE AND RE-NUMBER NOTES. |
| | 12) SHT M-4 RELIEF (T/P) VALVE DISCHARGE |
| | SHALL NOT BE TRAPPED. SEC 504.7.1 |
| | WATER HEATER REQUIRES THERMAL EXPANSION |
| | CONTROL. SEC 607.3.2. PLEASE SHOW ON DE- |
| | TAIL. |
| | |
| | REVIEW BY KEN STEVENS |
| | (561) 659-8096 EXT 8377 |