Plan Review Notes
Plan Review Notes For Permit 02091172
Permit Number 02091172
Review Stop B
Sequence Number 2
Notes
Date Text
2002-11-07 00:00:00PROVISO:
  
 1 1/2 HR RATED DOORS ARE REQUIRED IN THE
 2 HR RATED OCCUPANCY SEPARATION.FBC
 705.1.2 AND STAIR ENCLOSURE.
  
 PROVIDE SIGNED AND SEALED SHOP DRAWINGS
 FOR THE "TYPICAL DECK FRAMING DETAIL" ON
 SHEET S-1.INCLUDE SPAN, SIZE OF
 FRAMING MEMBER, TYPE AND NUMBER OF
 FASTENERS.