| Date |
Text |
| 2002-09-16 00:00:00 | FAILED : |
| | 1. THE EXISTING TRAFFIC SIGN AS SHOWN AT |
| | NW CORNER MUST BE RELOCATED PER CITY |
| | ENGINEER' OFFICE DIRECTION, 659-8040 |
| | 2. THE H.C PARKING CURB CUT AS SHOWN AT |
| | SOUTH END OF THE BUILDING IS NOT NEEDED |
| | IF THE CURB CUT AT THE 14' ALLEY CAN BE |
| | USED, VERIFY. |
| | 3. THE TREE GREAT AS SHOWN AT SOUTH |
| | END OF THE BUILDING SEEMS TO BE IN |
| | CONFLICT WITH EXISTING CATCH BASIN AND |
| | PROPOSED 12" PVC ROOF DRAIN. PLEASE |
| | VERIFY. |
| | 4. IS THE EXISTING POWER POLE(NORTH END) |
| | IN CONFLICT WITH THE BUILDING FOUNDATION |
| | ?IF SO COORDINATION WITH UTILITY COMPANY |
| | FOR RELOCATION WOULD BE REQUIRED. |
| | 5. LOCATING THE DDCV AND RPZ IN THE SIDE |
| | WALK IS NOT ACCEPTABLE UNLESS APPROVED |
| | BY THE PUBLIC UTILITIES ENGINEEERING |
| | SERVICES. NOTE: FIRE SPRINKLER PLANS |
| | SHOWS DDCV AND CONNECTIONS IN DEFFERENT |
| | LOCATION, PLEASE COORDINATE. |
| | 6. A CURB CUT FOR THE PROPOSED ROLED OUT |
| | DUMPSTERS WILL BE REQUIRED. |
| | 7. SHEET 3 OF 4 SHOWS DETAILS FOR 90 DEG |
| | PARKING STALL STRIPPING, SHEET 2 OF 4 |
| | SHOWS 60 DEG. PARKING STALLS. |
| | 8. SHEET 3 OF 4 SHOWS DETAILS FOR |
| | EXFILTRATION TRENCH AND CONTROL |
| | STRUCTURE, ETC., PLEASE SHOW LOCATIONS, |
| | LENGTHS,ETC.,IF USED. |
| | 9. PLEASE SHOW DETAILS FOR INSTALLATION |
| | OF METER BOXES IN SIDEWALK.SEE ATTACHED |
| | IF ANY QUESTIONS PLEASE CONTACT 659-8096 |
| | EXT. 8492 MOHAMMAD R. AMINI |