 BUILDING PLAN REVIEW
 PERMIT: 02090128
 ADD: 1386 N MANGONIA DR
 CONT: O/B CRAWFORD, CURTIS
 TEL: (561)833-9457
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1) PLANS, SPECIFICATIONS,REPORTS OR
 OTHER DOCUMENTS PREPARED BY THE DESIGN
 PROFESSIONAL AND BEING FILED FOR PUBLIC
 RECORD SHALL HAVE THE SIGNATURE AND
 SEAL OF THE DESIGN PROFESSIONAL AFFIXED
 TO THE DOCUMENT.
 FL STATE STAT: 61G15-23.002 ENGINEERS
 FL ATATE STAT: 61G16.003 ARCHITECTS
 SOILS REPORT TO BE SEALED BY THE SOILS
 ENGINEER. SOILS REPORT TO ALSO GIVE THE
 FOLLOWING INFORMATION:
 A) A 15 FT STANDAARD PENETRATION TEST-
 TO DETERMINE BASIC SOIL BEARING
 CAPACITY,
 B) SOILS PROFILE OF SUPPLEMENTAL 10 FT
 AUGERS
 C) THE MINIMUM SAFE BEARING VALUE OF
 THE SOIL
 D) IF DELETERIOUS MATERIAL(MUCK, SILT)
 MUST BE REMOVED THE REPORT SHALL CON
 TAIN DETAILED SPECIFICATIONS FOR
 REMOVAL
 E) IF PILING IS RECOMMENDED IT SHALL BE
 SO STATED AND ACCOMPANIED BY THE
 APPROPRIATE PILING SPECIFICATIONS
 F) SHOULD ADDITIONAL FILL BE REQUIRED
 WITHIN THE BOUNDARY OF THE STRUCTURE
 SPECIFICATIONS SHALL INCLUDE THE
 PROPER PLACEMENT AND COMPACTION.
  
 2)PROVIDE ENERGY CALCULATIONS AND
 EQUIPMENT SIZING CALCULATIONS (MANUAL J)
 AS REQUIRED BY THE 2001 FLORIDA ENERGY
 EFFICIENTCY CODE FOR BUILDING CONSTRUC-
 TION.
  
 3) FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORT, SBCCI OR DADE COUNTY
 REPORT ARE ACCEPTED.
 1606.1.4(1) IN WIND BORNE DEBRIS
 REGIONS, EXTERIOR GLAZING THAT RECEIVES
 POSITIVE PRESSURE IN BUILDINGS SHALL BE
 ASSUMED TO BE OPENINGS UNLESS SUCH
 GLAZING IS IMPACT RESISTANT OR PROTECTED
 WITH AN IMPACT RESISTANT COVERING MEET-
 ING THE REQUIREMENTS OF SSTD 12, ASTM
 E 1886 AND ASTM E 1996 OR MIAMI-DADE.
  
 1) GLAZED OPENINGS LOCATED WITHIN 30 FT
 OF GRADE SHALL MEET THE REQUIREMENTS OF
 LARGE MISSLE TEST. MISSING REPORTS:
 A) WINDOWS
 B)EXTERIOR DOORS
 C) ROOFING ASSEMBLIES
  
 4)1707.4.4.1 ANCHOR REQUIREMENTS:
 WINDOW & DOOR ASSEMBLIES SHALL BE ANCHOR
 ED IN ACCORDANCE WITH THE PUBLISHED
 MANUFACTURER'S RECOMMENDATIONS TO
 ACHIEVE THEDESIGN PRESSURE SPECIFIED.
 SUBSTITUTE ANCHORING SYSTEM USED FOR
 THE SUBSTRATE NOT SPECIFIED BY THE
 FENESTRATION MANUFACTURER SHALL PROVIDE
 EQUAL OR GREATER ANCHORING AS DEMONSTRA-
 TED BY ACCEPTED ENGINEERING PRACTICES.
  
 5) FL BLD CODE 2309.6 ATTIC ACCESS, PRO-
 VIDE ATTIC ACCESS 20"X36".
  
 6)1804.1.3 THE BOTTOM OF THE FOUNDA-
 TION SHALL EXTEND NO LESS THAN 12"
 BELOW FINISH GRADE.SHEET 4 OF 5 INDI-
 CATES ONLY 8" BELOW GRADE.
  
 7)FL BLD CODE 104.2.1.2
 ADDITIONAL INFORMATION REQUIRED,
 GABLE END WALLS, MISSING DETAIL FOR
 POSITIVE/ NEGATIVE PRESSURES, STRAPPING,
 VERTICAL REINFORCEMENT, GABLE END WITH
 2'-0" OVERHANG (DROPPED TRUSS), END ZONE
 3 REQUIREMENTS!
  
 8) CONSTRUCTION VALUES LOW, CALCULATED
 VALUE IS $79,073.00, ADDITIONAL PERMIT
 VALUE IS $708.20.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A
 DESCRIPTION OF THE REVISION MADE, IDEN-
 TIFYING THE SHEET OR SPECIFICATION PAGE
 WHERE THE CHANGES CAN BE FOUND, WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU
 FOR YOUR ANTICIPATED COOPERATION.