Plan Review Notes
Plan Review Notes For Permit 02081899
Permit Number 02081899
Review Stop P
Sequence Number 1
Notes
Date Text
2002-09-09 00:00:00DENIED
 REFERENCE: FBC-2001 CHAPTER 11
 FBC-2001 PLUMBING
  
 1) TOILET ROOM SHALL COMPLY WITH SECTION
 11-4.22 AND ALL SUBSECTIONS.
 DOOR SHALL NOT SWING INTO CLEAR FLOOR
 SPACE OR UNOBSTRUCTED 5' TURNING RADIUS.
 LAV HEIGHT - W/C HEIGHT - W/C SHALL BE
 18" OFF WALL TO CENTER OF FIXTURE - GRAB
 BARS - ECT. PLEASE PROVIDE DETAILS FOR
 TOILET ROOM
 2) TABLE 403.1 REQUIRES A DRINKING FOUN-
 TAIN. ALSO SEE SECTION 410.1 IF A WATER
 COOLER IS USED IT SHALL COMPLY WITH ARI-
 1010. PLEASE PROVIDE MANUF. INFO FOR
 WATER COOLER IF USED.
  