2003-02-06 00:00:00BUILDING PLAN REVIEW
 ******PROVISO*******
 ROBERT BROWN(561) 659 8096 EXT 8499
  
 FBC = FLORIDA BUILDING CODE 2001
 FBC*= FLORIDA BUILD'G CODE (CITY AMEND)
  
 --INFORMATIVE--
 FBC 3401.7.2.5REPAIRS AND ALTERATIONS
 AMOUNTING TO OVER 25% BUT NOT EXCEEDING
 50% OF THE EXISTING BUILDING'S VALUE CAN
 BE MADE WITHOUT MAKING THE ENTIRE
 EXISTING BUILDING COMPLY, PROVIDED SUCH
 REPAIRS AND ALTERATIONS COMPLY WITH THE
 REQUIREMENTS OF THE CODE.SEE PROVISOS
 BELOW.
  
 --PROVISO--
 FBC 1005.4.1EGRESS WINDOWS.THE
 REPLACEMENT BEDROOM WINDOWS SHALL BE
 EGRESS WINDOWS WITH A MIN. CLEAR OPENING
 OF 24" HIGH X 20" WIDE BUT NOT LESS THAN
 5.7 SQ FT.
  
 --PROVISO--
 FBC 1707.4.2.1 PROVIDE PRODUCT APPROVALS
 FOR THE REPLACEMENT WINDOWS AND EXTERIOR
 DOORS.
  
 --PROVISO--
 FBC 2405.2THE REPLACEMENT BATHROOM
 WINDOW GLAZING IS IN A 'HAZARDOUS
 LOCATION' AND IS REQUIRED TO BE SAFETY
 GLASS SATISFYING THE REQUIREMENTS OF THE
 CONSUMER PRODUCT SAFETY COMMISSION 16,
 CODE OF FEDERAL REGULATIONS, PART 1201
 (CPSC 16-CFR, PART 1201).
  
 --PROVISO--
 FBC 2309.6ATTIC ACCESS OPENING.
 NOTE 10 STATES "THIS CEILING HAS BEEN
 REPLACED", BUT THIS NOTE HAS NOT BEEN
 CALLED UP ANYWHERE ON THE PLANS.IF A
 NEW CEILING IS PROPOSED IT SHALL
 INCORPORATE AN ATTIC ACCESS OPENING NOT
 LESS THAN 20"X30".
  
 --PROVISO--
 FBC 1606.3SUBMIT A PRODUCT APPROVAL
 FOR THE PROPOSED 'FIBERGLAS' SHINGLES.