| | BUILDING PLAN REVIEW |
| | PERMIT: 02081787 |
| | ADD: 501 N WARE DRIVE |
| | CONT: O/B DIXON,TONDA |
| | TEL: (561)689-4964 |
| | FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| | |
| | 1) ADMINISTRATIVE CODE 104.2.1.3 |
| | QUALITY OF BUILDING PLANS. BUILDING |
| | PLANS SHALL BE DRAWN TO A MINIMUM 1/8TH |
| | INCH SCALE. THE BUILDING OFFICIAL MAY |
| | ESTABLISH THROUGH DEPARTMENTAL POLICY, |
| | STANDARDS FOR PLANS AND SPECIFICATIONS |
| | IN ORDER TO PROVIDE CONFORMITY TO ITS |
| | RECORD RETENTION PROGRAM. |
| | |
| | 2) 104.3.1.1 MINIMUM PLAN REVIEW CRITER- |
| | IA FOR BUILDING PLAN REVIEW: |
| | A) SURVEY OR SITE PLAN |
| | B) FIRE RESISTANCE CONSTRUCTION, TYPE |
| | OF BUILD I-VI |
| | C) FIRE AND OR SMKE DETECTORS |
| | D) EGRESS - WINDOW SIZE AND LOCATION |
| | E) STRUCTURAL REQUIREMENTS SHALL IN- |
| | CLUDE THE FOLLOWING: |
| | 1) FLOOR PLAN OF EXIST & NEW WORK |
| | 2) WALL SECTIONS FROM FOUNDATION |
| | THROUGH ROOF |
| | 3) INCLUDE ASSEMBLIES AND MATERIALS |
| | 4) CONNECTOR TABLES |
| | 5) WIND REQUIREMENTS |
| | 6)STRUCTURAL CALCS |
| | |
| | 3) PLANS NOT DESIGNED BY A DESIGN PROFES |
| | SIONAL SHALL BE DESIGNED UNDER: |
| | 1606.1.1 EXC (4) AF&PA WOOD FRAME |
| | CONSTRUCTION MANUAL FOR ONE & TWO |
| | FAMILY - 1995 SBC HIGH WIND EDITION |
| | 1996 SHALL BE PERMITTED FOR APPLICABLE |
| | WOOD FRAME BUILDINGS OF GROUP 3 OCCU- |
| | PANCY FOR A BABIC WIND SPEED OF 146 MPH |
| | OR LESS IN EXPOSURE B AND 124MPH OR LESS |
| | IN EXPOSURE C IN ACCORDANCE WITH FIGURE |
| | 1606 AND SECTION 1606.1.8. |
| | |
| | 4)FIGURE 1606 WIND-BORNE DEBRIS |
| | REGION; INDICATES THAT W.P.B. CITY OF IS |
| | LOCATED IN THE 140 MPH ZONE. PLANS ARE |
| | TO INDICATE THIS. |
| | |
| | 5)FL. BLD CODE 1606.1.7 THE FOLLOWING |
| | INFORMATION RELATED TO WIND SHALL BE |
| | SHOWN ON THE CONSTRUCTION DRAWINGS, |
| | 1)- BASIC WIND SPEED, MPH |
| | 2)- WIND IMPORTANCE FACTOR, & BUILDING |
| | CATEGORY |
| | 3)- WIND EXPOSURE |
| | 4)- INTERNAL PRESSURE COEFFICIENT, |
| | 5)- COMPONENTS & CLADDING, THE DESIGN |
| | WIND PRESSURES IN TERMS OF PSF. |
| | |
| | BEFORE A PERMIT TO CONSTRUCT, MAY |
| | BE ISSUED, IMPACT FEES MUST BE PAID TO |
| | PALM BEACH COUNTY. THE ACTUAL PERMIT |
| | SET OF PLANS MUST BE STAMPED BY THAT |
| | OFFICE, AND A COPY OF THE PAID RECEIPT |
| | ATTACHED TO THE PERMIT APPLICATION. |
| | PLEASE CALL (561)233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | LOOK FOR COMMENTS BY THE OTHER PLAN |
| | REVIEW DISCIPLINES THAT MAY BE WRITTEN |
| | ON THE APPLICATION, PLANS, OR ATTACHED |
| | SEPARATELY. WHEN RESUBMITTING PLANS |
| | PLEASE CLEARLY INDICATE THE REVISION AND |
| | REMOVE AND REPLACE ANY PAGES AS NECESS- |
| | ARY. A TRANSMITTAL LETTER LISTING THE |
| | ORIGINAL REVIEW COMMENT NUMBER, WITH A |
| | DESCRIPTION OF THE REVISION MADE, IDEN- |
| | TIFYING THE SHEET OR SPECIFICATION PAGE |
| | WHERE THE CHANGES CAN BE FOUND, WILL |
| | HELP TO EXPEDITE YOUR PERMIT. THANK YOU |
| | FOR YOUR ANTICIPATED COOPERATION. |