Date Text
2002-09-27 00:00:00 
 BUILDING PLAN REVIEW
 PERMIT: 02081787
 ADD: 501 N WARE DRIVE
 CONT: O/B DIXON,TONDA
 TEL: (561)689-4964
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1) ADMINISTRATIVE CODE 104.2.1.3
 QUALITY OF BUILDING PLANS. BUILDING
 PLANS SHALL BE DRAWN TO A MINIMUM 1/8TH
 INCH SCALE. THE BUILDING OFFICIAL MAY
 ESTABLISH THROUGH DEPARTMENTAL POLICY,
 STANDARDS FOR PLANS AND SPECIFICATIONS
 IN ORDER TO PROVIDE CONFORMITY TO ITS
 RECORD RETENTION PROGRAM.
  
 2) 104.3.1.1 MINIMUM PLAN REVIEW CRITER-
 IA FOR BUILDING PLAN REVIEW:
 A) SURVEY OR SITE PLAN
 B) FIRE RESISTANCE CONSTRUCTION, TYPE
 OF BUILD I-VI
 C) FIRE AND OR SMKE DETECTORS
 D) EGRESS - WINDOW SIZE AND LOCATION
 E) STRUCTURAL REQUIREMENTS SHALL IN-
 CLUDE THE FOLLOWING:
 1) FLOOR PLAN OF EXIST & NEW WORK
 2) WALL SECTIONS FROM FOUNDATION
 THROUGH ROOF
 3) INCLUDE ASSEMBLIES AND MATERIALS
 4) CONNECTOR TABLES
 5) WIND REQUIREMENTS
 6)STRUCTURAL CALCS
  
 3) PLANS NOT DESIGNED BY A DESIGN PROFES
 SIONAL SHALL BE DESIGNED UNDER:
 1606.1.1 EXC (4) AF&PA WOOD FRAME
 CONSTRUCTION MANUAL FOR ONE & TWO
 FAMILY - 1995 SBC HIGH WIND EDITION
 1996 SHALL BE PERMITTED FOR APPLICABLE
 WOOD FRAME BUILDINGS OF GROUP 3 OCCU-
 PANCY FOR A BABIC WIND SPEED OF 146 MPH
 OR LESS IN EXPOSURE B AND 124MPH OR LESS
 IN EXPOSURE C IN ACCORDANCE WITH FIGURE
 1606 AND SECTION 1606.1.8.
  
 4)FIGURE 1606 WIND-BORNE DEBRIS
 REGION; INDICATES THAT W.P.B. CITY OF IS
 LOCATED IN THE 140 MPH ZONE. PLANS ARE
 TO INDICATE THIS.
  
 5)FL. BLD CODE 1606.1.7 THE FOLLOWING
 INFORMATION RELATED TO WIND SHALL BE
 SHOWN ON THE CONSTRUCTION DRAWINGS,
 1)- BASIC WIND SPEED, MPH
 2)- WIND IMPORTANCE FACTOR, & BUILDING
 CATEGORY
 3)- WIND EXPOSURE
 4)- INTERNAL PRESSURE COEFFICIENT,
 5)- COMPONENTS & CLADDING, THE DESIGN
 WIND PRESSURES IN TERMS OF PSF.
  
 BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A
 DESCRIPTION OF THE REVISION MADE, IDEN-
 TIFYING THE SHEET OR SPECIFICATION PAGE
 WHERE THE CHANGES CAN BE FOUND, WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU
 FOR YOUR ANTICIPATED COOPERATION.
 JIM WITMER
 PLAN REVIEW
 TEL: (561)659-8096 EX.8412
 FAX: (561)659-8026