Plan Review Notes
Plan Review Notes For Permit 02081593
Permit Number 02081593
Review Stop B
Sequence Number 2
Notes
Date Text
2003-08-12 00:00:00*****CORRECTIONS*******
  
 SAMANTHA THYNG, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)SEE PREVIOUS CORRECTION LIST ITEM
 #2, SIGN OWNER/AGENT LINE OF THE ENERGY
 CALC.
  
 2.)SEE PREVIOUS CORRECTION LIST, ITEM
 #8.THIS AREA IS ONE OF QUESTIONABLE
 SOILS.PROVIDE AN ENGINEER'S REPORT
 CERTIFYING THE FOOTERS AND SLAB.
  
 3.)ITEM #5 WAS NOT ADDRESSED.SHOW
 OPENINGS BETWEEN THE EXISTING HOUSE AND
 PORCH.ARE THESE OPENINGS TO BE
 ALTERED?IF NOT, IMPACT PROTECTION IS
 OPTIONAL.IF THEY ARE BEING CHANGED
 (EX: DOOR REMOVED), IMPACT PROTECTION
 IS REQUIRED FBC1606.1.4, FBC3401.7.2.4.
  
 4.)AS THIS IS AN UNCONVENTIONAL
 DESIGN (TIE BEAM ATTACHED TO WOOD BEAM),
 HAVE A STRUCTURAL ENGINEER CERTIFY
 THE DESIGN.
  
 5.)SEE PREVIOUS CORRECTION LIST, ITEM
 16.A FIRESTOP WAS SHOWN IN THE
 ROOF JOISTS.SHOW FIRESTOP FOR THE
 WALLS, FBC705.3.1.
  
 6.)SEE PREVIOUS CORRECTION LIST, ITEM
 #17.WALL SECTION SHOWS A 1X8, NOTE AT
 TOP LEFT OF PLAN SHOWS A 2X8.
  
 7.)REFERENCE IS MADE TO "FL BLDG CODE
 3002".REVISE.
  
 8.)PROVIDE WIND DESIGN INFORMATION
 ON THE PLAN AS REQUIRED FBC1606.1.7.
  
 9.)PROVIDE AREA CALCULATIONS ON THE
 PLAN; EXISTING AND PROPOSED, NEW TOTAL.
  
 10.) WHEN RESUBMITTING, SUBMIT ALL OLD
 SHEETS AND CLOUD ALL CHANGES TO THE
 PLAN.