Plan Review Notes
Plan Review Notes For Permit 02081324
Permit Number 02081324
Review Stop B
Sequence Number 1
Notes
Date Text
2002-09-08 00:00:00 
 BUILDING PLAN REVIEW
 PERMIT: 02081324
 ADD: *****LIBERTY ISLES*****
 ****MODEL "C"****
 CONT: HOME DYNAMICS
 TEL: (954)275-8569
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1) SHEET A-2 NOTE: MONOLITHIC CONCRETE
 FOUNDATION WITHOUT HOOKBARS DESIGN BY
 RATIONAL ANAYLIS, WHAT IS THE MINIMUM
 DOWEL EMBEDDMENT DEPTH WITH NO HOOKS?
 GARGE SECTION STEMWALL CONT DO THE
 DOWEL BARS REQUIRE EXTRA EMBEDDMENT TO
 REACH THE FOUNDATION PORTION OF THE
 STEMWALL DESIGN?
  
 2) DESIGN NOTES SHEET A-3 INDICATE 130
 MPH, WE ARE LOCATED IN A 140 MPH WIND
 ZONE. ALSO WIND LOADS AS PER CHAPTER 16,
 AND ASCE 7-98.
  
 3) TABLE 2306.1 PALM BEACH COUNTY
 AMENDMENTS
 ROOF SHEATHING NAILING REQUIREMENTS
  
 ZONE 1 & 28D COMMON
 6" EDGES & 6" INTERMEDIATES
  
 ZONE 38DCOMMON
 4" EDGES & 6" INTERMEDIATES
  
 4) PROVIDE KEY PLAN FOR THE INSTALLATION
  
 SCHEDULE/ STORM SHUTTERS.
 JIM WITMER
 PLAN REVIEW
 (561)659-8096 X 8412


Account Summary | Usage Policy | Privacy Policy