| Date |
Text |
| 2002-08-28 00:00:00 | |
| | BUILDING PLAN REVIEW |
| | PERMIT: 02080606 |
| | ADD: 10250 HERONWOOD LANE |
| | CONT: CODE, INC |
| | TEL: (561)840-6590 |
| | FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| | |
| | 1)1606.1.4(1) IN WIND BORNE DEBRIS |
| | REGIONS, EXTERIOR GLAZING THAT RECEIVES |
| | POSITIVE PRESSURE IN BUILDINGS SHALL BE |
| | ASSUMED TO BE OPENINGS UNLESS SUCH |
| | GLAZING IS IMPACT RESISTANT OR PROTECTED |
| | WITH AN IMPACT RESISTANT COVERING MEET- |
| | ING THE REQUIREMENTS OF SSTD 12, ASTM |
| | E 1886 AND ASTM E 1996 OR MIAMI-DADE. |
| | |
| | 1) GLAZED OPENINGS LOCATED WITHIN 30 FT |
| | OF GRADE SHALL MEET THE REQUIREMENTS OF |
| | LARGE MISSLE TEST. |
| | |
| | 2) FL BLD CODE 1606.1.5: COMPONENTS & |
| | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- |
| | OLD OR RESIDENT INSPECTOR) OF PRODUCT |
| | TESTING REPORT, SBCCI OR DADE COUNTY |
| | REPORT ARE ACCEPTED. MISSING REPORTS: |
| | A) SINGLE HUNG WINDOW- ONLY 1 COPY |
| | B) FIXED GLASS |
| | C) BUTT GLASS DISCREPANCY 3/8"VS3/4" |
| | D) SLIDING GLASS DOOR |
| | E) STORM SHUTTERS |
| | F) ROOF ASSEMBLIES |
| | |
| | SINGLE HUNG WINDOW- PROVIDE 2 COPIES OF |
| | REPORT. |
| | |
| | FIXED GLASS ARCH SHEET DISCBIBING THE |
| | USE OF 3/8" THICK GLASS VS ENGINEERED |
| | SHEET USING 3/4" THICK GLASS. ALSO |
| | ARCH DETAILS DEPICT FIXED GLASS VS |
| | BUTT GLASS? |
| | |
| | SLIDING GLASS DOORS- EITHER SUBMIT PRO- |
| | DUCT TESTING REPORT, (2 COPIES) OR SUB- |
| | MIT A RECORD RESEARCH REQUEST FOR THE |
| | PLANS OF EXISTING STRUCTURE, THERE IS |
| | A FEE INVOLVED FOR RECORD RESEARCH RE- |
| | QUEST. |
| | |
| | STORM SHUTTERS ARE REQUIRED SINCE THE |
| | BUTT GLAZING DOES NOT HAVE LARGE MISSLE |
| | IMPACT REPORT!!! THE SAME HOLDS TRUE FOR |
| | ALL GLAZED UNITS BEING ADDED TO THE ADDI |
| | TION.STORM SHUTTERS REQUIRE: |
| | FL BLD CODE 2001 SECTION 103.6, |
| | 1606.1.4, 1707.4 & 3401.7.2.4. |
| | PROCEDURES: 1(B) A COMPLETE INSTALLATION |
| | SCHEDULE SUMMARIZING & IDENTIFYING |
| | OPENING SIZES, STORY HEIGHTS, UNIT MARK |
| | NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM |
| | BAR REINFORCING REQUIREMENTS, WALL PRES- |
| | SURE ZONES, SLAT TYPES, ETC., SHALL BE |
| | SUBMITTED AT TIME OF PERMIT APPLICATION |
| | TO FACILITATE PLAN REVIEW AND PERMIT |
| | ISSUANCE. |
| | |
| | ROOFING REPORT REQUIRED AS PER 1705. |
| | |
| | PROVIDE ENERGY CALCS PER 600.2.A.3. |
| | ADDITIONS: TO USE FORM 600C-01, SEE |
| | ATTACHMENT. |
| | |
| | THIRD REVIEWAS PER CITY CODE, 10% OF |
| | PERMIT FEE OR MINIMUM OF $50.00 WHICH- |
| | EVER IS GREATER. |
| | |
| | BUILDING PLAN REVIEW |
| | JIM WITMER |
| | (561)659-8096 X 8412 |