 BUILDING PLAN REVIEW
 PERMIT: 02080606
 ADD: 10250 HERONWOOD LANE
 CONT: CODE, INC
 TEL: (561)840-6590
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1)1606.1.4(1) IN WIND BORNE DEBRIS
 REGIONS, EXTERIOR GLAZING THAT RECEIVES
 POSITIVE PRESSURE IN BUILDINGS SHALL BE
 ASSUMED TO BE OPENINGS UNLESS SUCH
 GLAZING IS IMPACT RESISTANT OR PROTECTED
 WITH AN IMPACT RESISTANT COVERING MEET-
 ING THE REQUIREMENTS OF SSTD 12, ASTM
 E 1886 AND ASTM E 1996 OR MIAMI-DADE.
  
 1) GLAZED OPENINGS LOCATED WITHIN 30 FT
 OF GRADE SHALL MEET THE REQUIREMENTS OF
 LARGE MISSLE TEST.
  
 2) FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORT, SBCCI OR DADE COUNTY
 REPORT ARE ACCEPTED. MISSING REPORTS:
 A) SINGLE HUNG WINDOW- ONLY 1 COPY
 B) FIXED GLASS
 C) BUTT GLASS DISCREPANCY 3/8"VS3/4"
 D) SLIDING GLASS DOOR
 E) STORM SHUTTERS
 F) ROOF ASSEMBLIES
  
 SINGLE HUNG WINDOW- PROVIDE 2 COPIES OF
 REPORT.
  
 FIXED GLASS ARCH SHEET DISCBIBING THE
 USE OF 3/8" THICK GLASS VS ENGINEERED
 SHEET USING 3/4" THICK GLASS. ALSO
 ARCH DETAILS DEPICT FIXED GLASS VS
 BUTT GLASS?
  
 SLIDING GLASS DOORS- EITHER SUBMIT PRO-
 DUCT TESTING REPORT, (2 COPIES) OR SUB-
 MIT A RECORD RESEARCH REQUEST FOR THE
 PLANS OF EXISTING STRUCTURE, THERE IS
 A FEE INVOLVED FOR RECORD RESEARCH RE-
 QUEST.
  
 STORM SHUTTERS ARE REQUIRED SINCE THE
 BUTT GLAZING DOES NOT HAVE LARGE MISSLE
 IMPACT REPORT!!! THE SAME HOLDS TRUE FOR
 ALL GLAZED UNITS BEING ADDED TO THE ADDI
 TION.STORM SHUTTERS REQUIRE:
 FL BLD CODE 2001 SECTION 103.6,
 1606.1.4, 1707.4 & 3401.7.2.4.
 PROCEDURES: 1(B) A COMPLETE INSTALLATION
 SCHEDULE SUMMARIZING & IDENTIFYING
 OPENING SIZES, STORY HEIGHTS, UNIT MARK
 NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM
 BAR REINFORCING REQUIREMENTS, WALL PRES-
 SURE ZONES, SLAT TYPES, ETC., SHALL BE
 SUBMITTED AT TIME OF PERMIT APPLICATION
 TO FACILITATE PLAN REVIEW AND PERMIT
 ISSUANCE.
  
 ROOFING REPORT REQUIRED AS PER 1705.
  
 PROVIDE ENERGY CALCS PER 600.2.A.3.
 ADDITIONS: TO USE FORM 600C-01, SEE
 ATTACHMENT.
  
 THIRD REVIEWAS PER CITY CODE, 10% OF
 PERMIT FEE OR MINIMUM OF $50.00 WHICH-
 EVER IS GREATER.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 (561)659-8096 X 8412