Plan Review Notes
Plan Review Notes For Permit 02080563
Permit Number 02080563
Review Stop B
Sequence Number 5
Notes
Date Text
2003-04-10 00:00:00SHEET A46A.THE CALCULATIONS FOR FBC
 TABLE 600 FOR AREA OF PERMITTED WALL
 OPENINGS IS STILL INCORRECT.AS NOTED
 IN THE EARLIER CODE COMMENTS THE AREA
 IS DETERMINED ON A PER FLOOR BASIS.
  
 WALL AREAS IN THE SAME PLANE ON THE
 SAME FLOOR ARE CALCULATED AS A SINGLE
 UNIT.
  
 ON THE FIRST LEVEL AREAS SHOWN AS 40%
 ALLOWABLE EXCEED THAT IN TABLE 600.
 263 ALLOWED 450 SHOWN.
  
 SECOND LEVEL @ 40% ALLOWED 147 < 372
 SHOWN
  
 THIRD LEVEL @ 20% ALLOWED 430 < 850
 SHOWN.
  
 THIRD LEVEL @ 40% ALLOWED 147 < 328
 SHOWN.
  
 FOURTH LEVEL @ 40% ALLOWED 179 < 350
 SHOWN.
  
 FIFTH LEVEL @ 40% ALLOWED 147 < 372
 SHOWN.
  
 SIXTH LEVEL @ 20% ALLOWED 430 < 438
 SHOWN.
  
 SIXTH LEVEL @ 40% ALLOWED 147 < 353
 SHOWN.
  
 SEVENTH LEVEL @ 20% ALLOWED 276 < 386
 SHOWN.
  
 SEVENTH LEVEL @ 40% ALLOWED 147 < 372
 SHOWN.
  
 EIGHTH LEVEL @ 40% ALLOWED 161 < 250
 SHOWN.
  
 PLEASE REVISE AS NECESSARY.