2002-10-07 00:00:00DENIED
 REFERENCE: FBC-2001 CHAPTER 11
 FBC-2001 PLUMBING
 FHA AMEND-98 DESIGN MANUAL
  
 1) PLANS FOR POOL TOILET ROOM FACILITIES
 WILL BE ROUTED TO THE HEALTH DEPT WHEN
 THE POOL PERMIT IS APPLIED FOR.
 2) NO GREASE TRAP REQUIRED - CLICK CAFE
 IS ONLY A COFFEE HOUSE. NO FOOD SERVICE.
 3) FROM PREVIOUS REVIEW: SHTS A.93 THRU
 A-116 ALL UNITS SHALL COMPLY WITH RE-
 QUIREMENTS 1 THRU 7 AND SPECIFY SPECIFI-
 CATION "A" OR "B" AS REQUIRED FOR EACH
 UNIT ON PLANS. FHA DESIGN MANUAL
 4) FROM PREVIOUS REVIEW: SHT A.118 BACK-
 ING FOR TUBS AND SHOWERS SHALL COMPLY
 WITH FHA-98 DESIGN MANUAL. SHOW HEIGHT
 OFF FLOOR TO BOTTOM OF BACKING& HEIGHT
 & WIDTH OF ALL BACKING.
 5) FROM PREVIOUS REVIEW: PLEASE INDICATE
 WHERE RISER (S/23) IS LOCATED. UNABLE TO
 LOCATE BACK TO BACK P-5'S SHOWN ON RISER
 DIAGRAM.
 6) FROM PREVIOUS REVIEW: PLEASE SUBMIT A
 CONDENSATE RISER DIAGRAM FOR THE HORIZON
 TAL DRAIN AND RISERS. SHOW PIPE SIZES &
 TERMINATION. CONDENSATE SHALL TIE INTO
 THE STORM SYSTEM OR CATCH BASIN OUTSIDE
 THE BLDG. PLEASE SHOW REQUIRED RELIEF
 VENT.
  