| Notes |
| Date |
Text |
| 2002-08-14 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 11 | | | FBC-2001 PLUMBING | | | | | | 1) SHT A100 SERVICE SINK AND DRINKING | | | FOUNTAIN REQUIRED. TABLE 403.1 (ALSO SEE | | | SECTION 410.1. IF BOTTLE WATER COOLER IT | | | SHALL COMPLY WITH WHI-1010.) | | | 2) SHT A100 SINK IN KITCHENETTE SHALL | | | COMPLY WITH 11-4.24 AND ALL SUBSECTIONS. | | | DOOR SHALL NOT SWING INTO CLEAR FLOOR | | | SPACE FOR SINK SEC'S 11-4.17.5, 11-4.22. | | | 2 & 11-4.23.2 | | | 3) SHT A100 A WATER RISER IS REQUIRED. | | | WATER HAMMER ARRESTORS ARE REQUIRED PER | | | SECTION 604.9. LOCATION OF WHA'S SHALL | | | BE NEAR THE FIXTURE IN AN "EFFECTIVE | | | RANGE" NOT AT THE TOP OF THE DROP. | | | MANUFACTURE INSTALLATION INSTRUCTIONS & | | | PDI-WH 201. | | | 4) SHT A100 WOMENS TOILET ROOM, DOOR | | | SHALL NOT SWING INTO THE CLEAR FLOOR | | | SPACE OR UNOBSTRUCTED TURNING RADIUS OF | | | HDCP FIXTURES. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|