| 2002-09-30 00:00:00 | BUILDING PLAN REVIEW | | | ******PROVISO******* | | | ROBERT BROWN(561) 659 8096 EXT 8499 | | | | | | IT IS NOTED THAT THE PLANS HAVE BEEN | | | REVISED AND NOW SHOW AN INCREASED SCOPE | | | OF WORK, INCLUDING REMOVAL OF THE | | | EXISTING WOOD FLOOR SYSTEM, INSTALLATION | | | OF NEW STAIRWAYS, PLATFORM AND LANDINGS, | | | PLACEMENT OF NEW FLOOR SLAB AND | | | INSTALLATION OF NEW GARAGE DOOR AND EXIT | | | DOOR. | | | | | | --PROVISO-- | | | FBC 1015.2EACH NEW STAIRWAY, LANDING | | | AND PLATFORM SHALL INCORPORATE GUARDING | | | NOT LESS THAN 42" HIGH (PLANS SHOW 36" | | | HIGH). | | | | | | --PROVISO-- | | | SUBMIT TWO COPIES OF A PRODUCT APPROVAL | | | FOR THE NEW 3-0"X 6-8" STEEL EXIT DOOR | | | #2 AND #3.ALSO, PROVIDE LINTEL DETAILS | | | | | | --PROVISO-- | | | THE SUBMITTED COPIES OF DRAWING SHEETS | | | FOR PRODUCT APPROVAL NOA# 01-1031.08 FOR | | | THE SERIES 800 SERVICE DOOR ARE POOR | | | QUALITY.SUBMIT TWO LEGIBLE COPIES. |
|