| Notes |
| Date |
Text |
| 2002-09-07 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | 1) ONLY THE FIXTURES WITHIN THE BATHROOM | | | GROUPS SHALL CONNECT TO THE WET-VENTED | | | HORIZONTAL BRANCH DRAIN. SEC 909.1 | | | ANY ADDITIONAL FIXTURES SHALL DISCHARGE | | | DOWNSTREAM OF THE WET VENT. - THE LAUN- | | | DRY TRAY SHALL BE TIED IN DOWNSTREAM OF | | | THE VENT LINE FOR THE WATER CLOSET. SEE | | | RED LINE ON SHEET 1 SUBMITTED. | | | 2) SANITARY RISER DIAGRAM SHALL REFLECT | | | THE FLOOR PLAN. IF THE BLDG DRAIN IS | | | ENTERING THE BLDG FROM THE FRONT THEN | | | THE MASTER BATH SHALL BE SHOWN ON THE | | | RIGHT SIDE OF THE BLDG DRAIN AND BATH | | | #2 ON THE LEFT SIDE OF THE BLDG DRAIN | | | TO REFLECT THE FLOOR PLAN. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|