| Date |
Text |
| 2002-07-29 00:00:00 | DENIED |
| | REFERENCE: FBC-2001 CHAPTER 11 |
| | FBC-2001 PLUMBING |
| | |
| | 1) SHT DP 01 DEMO & REMOVE BLDG. IS |
| | THERE PLUMBING IN BLDG? IF SO A PLBG. |
| | PERMIT WILL BE REQUIRED FOR DEMO. |
| | 2) SHT IP 03 A RAIN SENSOR IS REQUIRED |
| | AT CONTROL AND PUMP STATION. SEPARATE |
| | IRRIGATION PERMIT REQUIRED. |
| | 3) SHT AA 02 PLEASE PROVIDE CALCULATIONS |
| | FOR DOWN SPOUTS AND SHOW SIZE OF DOWN |
| | SPOUTS. |
| | 4) BACK FLOWS ARE REQUIRED FOR WATER |
| | SERVICE FOR EACH BUILDING SERVICED WITH |
| | POTABLE WATER. REDUCED PRESSURE ZONE |
| | 5) SHT AMK 01 MARKET PLACE, PLEASE SUB- |
| | MIT A SANITARY & WATER RISER DIAGRAM. |
| | 6) SHT AMK 05 DETAIL #3, WATER CLOSET |
| | SHALL BE 1'6" OFF WALL TO CENTER OF |
| | FIXTURE. PLEASE SHOW ON DETAIL. |
| | 7) SHT AMK 05 SHOWER STALL DETAIL TO |
| | COMPLY WITH 11-4.21.7. CURBS SHALL BE NO |
| | HIGHER THAN 1/2". PLEASE SHOW ON DETAIL |
| | 8) SHT AMK 06 DRAIN FOR EMERGENCY SHOWER |
| | SHALL DRAIN TO STORM AT WATER TOWER. |
| | 9) SHT AMT 01 NO WATER OR SANITARY SHOWN |
| | ON UTILITY SITE PLAN FOR MARMOSET NIGHT- |
| | HOUSE. |
| | 10) SHT A0 01 OBSERVATORY, SANITARY & |
| | WATER RISER DIAGRAM REQUIRED. PLEASE |
| | PROVIDE. |
| | 11) SHT A0 01 SHOWS PLANTER DRAINS, BUT |
| | SHT A0 02 DETAIL SAYS STORM DRAINS. |
| | PLEASE CLAIRFY. PLEASE SHOW SIZE OF |
| | DRAINS AND SHOW WHERE THEY TERMINATE. |
| | 12) SHT AS 01 PLEASE PROVIDE A SANITARY |
| | & WATER RISER DIAGRAM FOR PRIMATE NIGHT- |
| | HOUSE. |
| | 13) SHT AT 01 WILL THE NELSON WATERS |
| | BE PIPED DIRECTLY? IF SO PLEASE PROVIDE |
| | A WATER RISER DIAGRAM FOR THE TAPIR/ |
| | LLAMA/CAPYBARA NIGHTHOUSE. |
| | |
| | REVIEW BY KEN STEVENS |
| | (561) 659-8096 EXT 8377 |