| Date |
Text |
| 2002-06-24 00:00:00 | |
| | BUILDING PLAN REVIEW |
| | PERMIT:02061420 |
| | ADD: 2068 STONINGTON TERR |
| | CONT: O/B MIGUEL MARTINEZ |
| | TEL: 795-1065 |
| | FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| | |
| | 1) FL BLDG CODE, ADMINISTRATIVE AMEND |
| | 104.2.1 ALL INFORMATION, DRAWINGS, SPEC- |
| | IFICATIONS AND ACCOMPANING DATA SHALL |
| | BEAR THE NAME AND SIGNATURE OF THE PER- |
| | SON RESPONSIBLE FOR THE DESIGN. |
| | |
| | 2)FL. BLD CODE 1606.1.7 THE FOLLOWING |
| | INFORMATION RELATED TO WIND SHALL BE |
| | SHOWN ON THE CONSTRUCTION DRAWINGS, |
| | 1)- BASIC WIND SPEED, MPH |
| | 2)- WIND IMPORTANCE FACTOR, & BUILDING |
| | CATEGORY |
| | 3)- WIND EXPOSURE |
| | 4)- INTERNAL PRESSURE COEFFICIENT, |
| | 5)- COMPONENTS & CLADDING, THE DESIGN |
| | WIND PRESSURES IN TERMS OF PSF. |
| | |
| | 3) FL BLD CODE 1606.1.5: COMPONENTS & |
| | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- |
| | OLD OR RESIDENT INSPECTOR) OF PRODUCT |
| | TESTING REPORT, SBCCI OR DADE COUNTY |
| | REPORT ARE ACCEPTED. PROVIDE PRODUCT OR |
| | SITE SPECIFIC ENGINEERING (PRODUCT |
| | APPROVAL) REQUIRES THE WET SIGNATURE, |
| | DATE AND EMBOSSED SEAL OF THE ENGINEER |
| | CERTIFYING THE PRODUCT AND SIGNATURE |
| | AND SEAL OF THE DESIGN PROFESSIONAL |
| | OF RECORD. |
| | PLAN REVIEW |
| | JIM WITMER |
| | (561) 659-8096 X 8412 |