| Date |
Text |
| 2002-08-05 00:00:00 | BUILDING DENIED |
| | |
| | 1) IMPACT FEES MUST BE PAID TO PALM |
| | BEACH COUNTY, PLANS STAMPED BY THEM AND |
| | COPY OF RECEIPT SUBMITTED TO CITY OF |
| | WEST PALM BEACH BUILDING DEPARTMENT, |
| | BEFORE A BUILDING PERMIT CAN BE ISSUED. |
| | |
| | 2) 2001 FBC SECTION 1909.3 REQUIRES |
| | THE WELDED WIRE MESH IN THE SLAB TO BE |
| | SUPPORTED WITH THE SPACING BETWEEN |
| | SUPPORTS NOT TO EXCEED THREE (3) FEET. |
| | PLEASE REVISE NOTES ON S1 AND S5. |
| | |
| | 3) DRAFTSTOPPING OF THE FLOOR/CEILING |
| | SPACE IS REQUIRED BY 2001 FBC 2305.2.2. |
| | PLEASE REVISE NOTE ON S1 TO REFERENCE |
| | 2001 FBC AND INDICATE WHAT TYPE OF 5/8" |
| | MATERIAL WILL BE USED. |
| | |
| | 4) PLEASE REVISE DETAIL 8 ON S4 TO |
| | REFERENCE THE 2001 FBC. |
| | |
| | 5) REVISE NOTE 4 UNDER GENERAL NOTES ON |
| | S4 TO CITY OF WEST PALM BEACH AMENDMENTS |
| | |
| | 6) INDICATE THE POSITIVE AND NEGATIVE |
| | WINDLOAD PRESSURES FOR THE SKYLIGHT AND |
| | GLASS BLOCK OPENINGS. |
| | |
| | 7) PLEASE INDICATE THE CALL SIZE FOR THE |
| | 2840 SH WINDOWS AT BEDROOM #2. THIS SIZE |
| | WINDOW DOES NOT MEET EMERGENCY EGRESS |
| | REQUIREMENTS FOR SECOND FLOOR. |
| | PROVIDE EMERGENCY EGRESS WINDOW IN |
| | SLEEPING ROOMS WITH A MINIMUM NET CLEAR |
| | OPENING HEIGHT OF 24INCHES,NET CLEAR |
| | OPENING WIDTH OF 20 INCHES AND NET CLEAR |
| | OPENING AREA OF 5.7 SQ.FT. GROUND FLOOR |
| | OPENINGS ARE PERMITTED TO HAVE A NET |
| | CLEAR OPENING OF 5.0 SQ.FT. SILL HEIGHT |
| | SHALL NOT BE MORE THAN 44 INCHES ABOVE |
| | THE FLOOR. 2001 FBC 1005.4 |
| | |
| | 8) PROVIDE THE COMPLETE PRODUCT APPROVAL |
| | FOR THE KDI STRUCTURAL WINDOW MULLIONS. |
| | (THREE SHEETS OF DRAWINGS WERE ALL THAT |
| | WAS SUBMITTED) |
| | |
| | 9) THE SBCCI PRODUCT EVALUATION REPORT |
| | IS LIMITED TO TWO PANEL SLIDING GLASS |
| | DOORS. THE PLANS INDICATE A THREE PANEL |
| | SGD AT THE MASTER BEDROOM. PLEASE |
| | SUBMIT THE APPROPRIATE PRODUCT APPROVAL. |
| | |
| | ROBERT MCDOUGAL |
| | BLDG. PLAN REVIEW |
| | (561)659-8096 EXT.8202 |