| Date |
Text |
| 2002-08-02 00:00:00 | CHECKLIST: |
| | 1-AFTER CORRECTIONS ARE DONE TO ORIGINAL |
| | DRAWINGS PAY IMPACT FEES. BRING BACK |
| | STAMPED DRAWINGS AND PAID RECEIPT. |
| | 2-NEED RECORDED NOTICE OF COMMENCEMENT. |
| | 3-UPDATE SURVEY. SEE RECORDED PLAT. |
| | 4-DRAWINGS TO HAVE ALL INFORMATION REQ'D |
| | BY SEC. 1606.1.7 FBC 2001 (MISSING THE |
| | INTERNAL PRESSURE COEFFICIENT. |
| | 5-REVISE GABLE ENDS DETAILS AS REQUIRED |
| | TO COMPLY WITH SEC. 2117 FBC 2001. |
| | 6-NEED ONE HOUR GLASS BLOCK ASSEMBLY AT |
| | ZERO LOT LINE. PROVIDE UL LISTING AND |
| | SPECS FOR ONE HR ASSEMBLY. |
| | NOTE: COORDINATE WITH PRODUCT APPROVAL |
| | SUBMITTED BY THE CONTRACTOR. |
| | 7-REVISE 2X BUCK DETAIL. SEE SECTION |
| | 1707.4.4.2 FBC 2001. |
| | 8-SEE GARAGE DOOR PRODUCT APPROVAL AND |
| | REVISE BUCK DETAIL AS REQUIRED. |
| | 9-PROVIDE DETAILS/SPECS FOR CEILING |
| | INSTALLATIONS AT ENTRY AND REAR PORCH. |
| | SEE ASTM C-1063 FOR PROPER FASTENERS |
| | AND METAL LATH. |
| | 10-SPECIFY POSTS TO RECEIVE TRUSS GIRDER |
| | SEE ROOF FRAMING PLAN. |
| | 11-SPECIFY CONCRETE SLAB JOINTS OR |
| | SPECIFY SUPPORTS FOR WWM. SEE SECTION |
| | 1909.3 FBC 2001. |
| | 12-IF TAKEN CEILING FANS CREDIT ON THE |
| | ENERGY CALCS, THEN, SPECIFY ON PLANS |
| | SIZES AS REQUIRED BY TABLE 6-6 CHAPTER |
| | 13 FBC 2001. |
| | 13-PROVIDE PRODUCT APPROVAL FOR: |
| | A)ENTRY DOOR WITH ONLY ONE SIDELITE |
| | ASSEMBLY AS SHOWN ON PLANS. |
| | B)WINDOW MULLIONS WITH CLIPS AS REQUIRED |
| | BY SEC. 1707.4.5.2 FBC 2001. |
| | C)ARCHED WINDOWS AS SHOWN ON PLANS. |
| | D)SLIDING GLASS DOORS WITH TRANSOM ABOVE |
| | SINGLE ASSEMBLY AS SHOWN ON PLANS. |
| | CHECK SIZE AND DESIGN PRESSURES. |
| | E)GLASS BLOCK. ONE HR ASSEMBLY. |
| | |
| | 14-SEE PLANS FOR ADDITIONAL COMMENTS AND |
| | PLEASE RETURN REVIEWED SET TO EXPEDITE |
| | REVIEW PROCESS. |