Plan Review Notes
Plan Review Notes For Permit 02061083
Permit Number 02061083
Review Stop M
Sequence Number 2
Notes
Date Text
2002-09-03 00:00:00PROVISO:
  
 ADDITIONAL PERMITS REQUIRED FOR HOOD,
 FIRE SUPRESSION, & WALK-IN COOLERS.
 PLEASE PROVIDE PLANS & MANUFACTURER
 SUBMITTAL DATA WITH PERMIT APPLICATION.
  
 PLEASE NOTE:
  
 EXHAUST FANS FOR HOOD/GREASE DUCT SHALL
 TERMINATE:
  
 (A) A MINIMUM OF 10 FT FROM ADJACENT
 BUILDINGS, PROPERTY LINES & AIR INTAKES.
  
 (B) TERMINATE A MINIMUM OF 40" ABOVE THE
 THE ROOF SURFACE.
  
 FAN SHUTDOWN BY DUCT SMOKE DETECTOR AS
 PER 2001 FBC(M) 606.2.2 IN ACCORDANCE
 WITH 606.4 OR 606.4.1.
  