| Plan Review Notes For Permit 02061076 |
| Permit Number |
02061076 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2002-07-10 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 11 | | | FBC-2001 PLUMBING | | | | | | 1) SHTS LS-1.01 & A-5.01 WOMEN'S TOILET | | | ROOM #011. THE ACCESSIBLE W/C SHALL BE | | | LOCATED IN THE CORNER DIAGONAL TO THE | | | DOOR. SEC. 11-4.17.3 & FIG. 30E. | | | 2) SHT A-5.01 PLEASE SHOW CLEAR FLOOR | | | SPACE FOR HDCP FIXTURES. 11-4.16.2 W/C, | | | 11-4.18.3 URNAL, & 11-4.19.3 LAV. | | | 3) SHT A-5.01 DETAIL #3, TOILET ROOM EL- | | | EVATION (H), URNAL HEIGHT SHALL BE 17" | | | PER 11-4.18.2 | | | 4) SHT A-5.01 DETAIL (I), W/C TO BE 1'6" | | | TO CENTER OFF WALL NOT 1'8" AS SHOWN. | | | SEE FIG. 30E. | | | 5) PLEASE SUBMITSANITARY AND WATER | | | RISER DIAGRAMS FOR TOILET ROOMS AND | | | BREWERY. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|