Plan Review Notes
Plan Review Notes For Permit 02060714
Permit Number 02060714
Review Stop B
Sequence Number 6
Notes
Date Text
2003-01-10 00:00:00BUILDING PLAN REVIEW
 PERMIT: 02060714 (MASTER)
 ADD: SITE 1600 PRESIDENTIAL WAY
 CONT: AVS CONSTRUCTION
 TEL: (###)###-####
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 GLAZED OPENING SUBMITTALS:
 DENIED
  
 1) ALL INFORMATION TO BE PROVIDED TO THE
 CITY SHALL BE SUBMITTED TO THE FRONT
 COUNTER, W/ REVISION/ SUBMITTAL FORM,
 LOGGED IN (DATE) TO BE REVIEWED!!!!!!
  
 2)SITE SPECIFIC ENGINEERING (PRODUCT
 APPROVAL) REQUIRES THE WET SIGNATURE,
 DATE AND EMBOSSED SEAL OF THE ENGINEER
 CERTIFYING THE PRODUCT AND SIGNATURE
 AND SEAL OF THE DESIGN PROFESSIONAL
 OF RECORD. CITY STANDARD REQUIRES WEST
 PALM BEACH FORM TO BE USED. IN USING
 THIS FORM THE CERTIFYING ENGINEER ENTERS
 THE INFORMATION ON THE LEFT SIDE OF THE
 FORM DATES, SIGNS AND SEALS THE FORM.
 THE DESIGN PROFESSIONAL FOR THE PROJECT
 REVIEWS THIS INFORMATION & CERTIFIES
 THIS INFORMATION MEETS THE REQUIREMENTS
 FOR THE 2001 FLORIDA CODE. DATES, SIGNS
 & SEALS THE RIGHT SIDE OF THE FORM.
  
 2) PGT SERIES SGD-70"OK" POS/NEG PRES-
 SURE AND FOR LARGE AND SMALL MISSLE
 RESISTANCE.
  
 3) PGT SERIES "PW701 ALUMINIUM FIXED
 WINDOWS""OK" FOR POS/NEG PRESSURE &
 FOR LARGE & SMALL MISSLE IMPACT.
  
 4) TRACO MULLION:
 DENIED
 SEE LIMITATIONS 4.2 INSTALATION OF THIS
 UNIT WILL REQUIRE STORM SHUTTERS.
 1707.4.5.2 MULLIONS SHALL BE DESIGN-
 ED TO TRANSFER THE DESIGN PRESSURE LOADS
 APPLIED BY THE WINDOW OR DOOR ASSEMBLIES
 TO THE ROUGH OPENING SUBTRATE. FOR
 WINDOWS TO BE USED FOR LARGE MISSLE IM-
 PACT RESISTANCE THE MULIONS ARE REQUIRED
 TO BE CLIPPED TO TRANSFER LOADS.
 1707.4.5.4 STRUCTURAL SAFETY FACTOR
 SEE CODE SECTION.
  
 ALL SHOP DRAWINGS SUBMITTALS TO BE RE-
 VIEWED BY THE DESIGNER OF RECORD,
 CLEMENT DIFILLPPO AIA. P.E.
  
 BUILDING PLAN REVIEW
 JIM WITMER