Plan Review Notes
Plan Review Notes For Permit 02060664
Permit Number 02060664
Review Stop B
Sequence Number 1
Notes
Date Text
2002-08-13 00:00:00 
 BUILDING PLAN REVIEW
 PERMIT: 02060664
 ADD: 228 9TH STREET
 CONT: TERRY SPARKS CONSTRUCTION
 TEL: (561)538-5218
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 *****BEDROOM/ BATH & EXERCISE ADD*****
  
 1) FL BLD CODE 1804.2.2 QUESTIONABLE
 SOILS, WHERE THE BEARING CAPACITY IS
 NOT DEFINETLY KNOWN OR IS IN QUESTION.
  
 2)PROVIDE ENERGY CALCULATIONS AND
 EQUIPMENT SIZING CALCULATIONS (MANUAL J)
 AS REQUIRED BY THE 2001 FLORIDA ENERGY
 EFFICIENTCY CODE FOR BUILDING CONSTRUC-
 TION.
  
 3)FIGURE 1606 WIND-BORNE DEBRIS
 REGION; INDICATES THAT W.P.B. CITY OF IS
 LOCATED IN THE 140 MPH ZONE. PLANS ARE
 TO INDICATE THIS.
  
 4)FL. BLD CODE 1606.1.7 THE FOLLOWING
 INFORMATION RELATED TO WIND SHALL BE
 SHOWN ON THE CONSTRUCTION DRAWINGS,
 1)- BASIC WIND SPEED, MPH
 2)- WIND IMPORTANCE FACTOR, & BUILDING
 CATEGORY
 3)- WIND EXPOSURE
 4)- INTERNAL PRESSURE COEFFICIENT,
 5)- COMPONENTS & CLADDING, THE DESIGN
 WIND PRESSURES IN TERMS OF PSF.
  
 5) FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORT, SBCCI OR DADE COUNTY
 REPORT ARE ACCEPTED.MISSING REPORTS:
 A) WINDOWS
 B) EXTERIOR DOORS W/ GLAZED OPENINGS
 C) STORM SHUTTERS
 D) ROOFING ASSEMBLIES
  
 6)SITE SPECIFIC ENGINEERING (PRODUCT
 APPROVAL) REQUIRES THE WET SIGNATURE,
 DATE AND EMBOSSED SEAL OF THE ENGINEER
 CERTIFYING THE PRODUCT AND SIGNATURE
 AND SEAL OF THE DESIGN PROFESSIONAL
 OF RECORD.
  
 7) PROVIDE STORM PANEL INFORMATION WITH
 INSTALLATION SCHEDULE AND KEY PLAN WITH
 SPECIFIC ANCHORS AND MOUNTING TO BE USED
 FOR ALL NON-IMPACT GLAZING.
 FBC 1606.1.4.
  
 8)FL BLD CODE 2001 SECTION 103.6,
 1606.1.4, 1707.4 & 3401.7.2.4.
 PROCEDURES: 1(B) A COMPLETE INSTALLATION
 SCHEDULE SUMMARIZING & IDENTIFYING
 OPENING SIZES, STORY HEIGHTS, UNIT MARK
 NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM
 BAR REINFORCING REQUIREMENTS, WALL PRES-
 SURE ZONES, SLAT TYPES, ETC., SHALL BE
 SUBMITTED AT TIME OF PERMIT APPLICATION
 TO FACILITATE PLAN REVIEW AND PERMIT
 ISSUANCE.
  
 10) 1606.4.4 ANCHOR METHODS. PROVIDE
 INFORMATION FOR INSTALLATION OF DOOR
 AND WINDOW BUCKS.
  
 11) FBC 1606.TRUSS & GIRDER LOADS,
 VERTICAL,HORIZONTAL AND GRAVITY LOADS,
 INDICATE ON TRUSS PLAN. INDICATE WITH
 ANCHOR SCHEDULE MANUFACTURE, MODEL &
 ALLOWABLE LOADS.
 1707.3.1 JOIST HANGERS, FRAMING
 ANCHORS & SIMILAR DEVICES SHALL BE TEST-
 ED IN ACCORDANCE W/ ASTM D 1761 & BE
 LABELED AND LISTED FOR THEIR LOAD CARRY-
 ING CAPACITY.
  
 12) FL BLD CODE 104.2.1.2
 ADDITIONAL INFORMATION REQUIRED, A-3
 TYPICAL WALL SECTION INDICATES THE USE
 OF R-30 INSULATION, WILL NOT FIT INTO A
 2X6 STUD WALL.
  
 13) PLEASE INDICATE WHAT TYPE OF HOLD
 DOWN FASTENERS ARE TO BE USED ON SIDES
 WINDOWS & DOORS?
  
 14) WALL SECTION INDICATES THE USE OF
 WOOD SUB-SHEATHING,WIRE LATH & STUCCO.
 2304.2.5 TO PROVIDE A 6" AIR GAP BETWEEN
 GRADE AND SUBSHEATHING,AND STUCCO.
 STUCCO NO LONGER CAN DIE INTO THE SOILS
 WITH WOOD BACKING.
  
 15)FL BLD CODE 2309.6 ATTIC ACCESS, PRO-
 VIDE ATTIC ACCESS 20"X36".
  
 16)FL BLD CODE 2405.2 HAZARDOUS LOCATION
 PROVIDE SAFETY GLASS FOR THIS LOCATION:
 A) TUB
 B) SWING DOORS
  
 17) 424.17.1.9 WHERE A WALL OF A DWELL-
 ING SERVES AS PART OF THE POOL BARRIER,
 SHOW SAFETY COMPLIANCE.
 BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
  
 ***1 STORY COVERED PATIO***
  
 1) SHOW COMPLIANCE WITH TABLE 600 ISSUE
 20 % OPENINGS.
  
 2) 1606.2.4.MAIN WIND FORCE RESISTING
 SYSTEM. PLANS ARE AT BEST A RENDERING
 OF AN OPEN COVERED PATIO. NO INFORMATION
 IS OFFERED AS TO HOW WIND LOADING IS
 TRANSFERRED FROM THE FOUNDATION THROUGH
 TO THE ROOF? NO DETAILS FOR BEAMS,
 ROOF FRAMING, SHEATHING, ROOF ASSEMBLIES
 ETC!!!!!!
  
 3) IS THERE AND EXISTING DOORWAY FROM
 THE BUILDING?
  
 NOTES IN GENERAL:
  
 1) THE FOUNTAIN IN FRONT YARD SHALL RE-
 QUIRE A SEPERATE PERMIT.
  
 2) FENCES AND EXTERIOR GARDEN OR PRIVACY
 WALLS REQUIRE A SEPERATE PERMIT, SUBMIT
 PLAN TO WATER DEPARTMENT FIRST FLOOR
 BEFORE SUBMITTING FOR PERMIT.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A
 DESCRIPTION OF THE REVISION MADE, IDEN-
 TIFYING THE SHEET OR SPECIFICATION PAGE
 WHERE THE CHANGES CAN BE FOUND, WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU
 FOR YOUR ANTICIPATED COOPERATION.
 JIM WITMER
 PLAN REVIEW
 TEL: (561)659-8096 EX.8412
 FAX: (561)659-8026