| Date |
Text |
| 2002-10-24 00:00:00 | APPROVED WITH PROVISO: |
| | 1-REVISE ENERGY CALCULATIONS: RAISED WD, |
| | AND ADJACENT WALLS ARE INCORRECT. SEE |
| | PLANS AND REVISE AS REQUIRED. |
| | 2-ARCHITECT TO CORRECT TOATAL A/C AREA |
| | ON DWGS C-1 AND A-1. |
| | 3-PROVIDE COMPLETE/CORRECT INFORMATION |
| | FOR STORM SHUTTERS UNDER A SEPARATE |
| | PERMIT. SEE CITY IMPLEMENTATION |
| | STANDARD FOR HURRICANE MISSILE IMPACT |
| | PROTECTION FOR SITE SPECIFIC CONDITION |
| | 4-SHEET A-5: REVISE HEIGHT OF HANDRAIL. |
| | SEE SEC. 1007.5.1 FBC 2001. |
| | 5-SHEET A-6: A)SPECIFY FIREBLOCKING AT |
| | SECTION A/A6. SEC. 2305.1.4 FBC 2001. |
| | B)SEE PRODUCT APPROVAL FOR GARAGE DOOR |
| | AND REVISE BUCK DETAIL AS REQUIRED. |
| | SPECIFY ANCHOR EMBEDMENT AND WASHER. |
| | SEC. 104.2.1.2 CITY AMENDMENTS TO FBC. |
| | 6-SPECIFY HOW LONG ARE THE ANCHOR BOLTS |
| | FOR WOOD COLUMN BOTTOM CONNECTOR. SEC. |
| | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. |
| | 7-SHEET S-2: CLARIFY SIZE OF BOND BEAM |
| | REINFORCEMENT SPECIFIED ON TYPICAL |
| | CONCRETE MASONRY WALL DETAIL. IS IT |
| | 1#5 OR 1#7?. SEC. 104.2.1.2 CITY AMEND |
| | 8-SHEET S-3: ROOF SHEATHING & NAILING |
| | NOTE AND DIAPHRAGM SCHEDULE SPECS DO |
| | NOT MATCH. CLARIFY SIZE OF NAIL AND |
| | SPACING. SEC. 104.2.1.2 AND TABLE |
| | 2306.1 CITY AMENDMENTS TO FBC 2001. |
| | 9-PROVIDE COMPLETE STRUCTURAL DETAIL AT |
| | RECESSED WINDOW TO RECEIVE STORM |
| | SHUTTERS. SEE STORM SHUTTERS PRODUCT |
| | APPROVAL FOR LIMITATIONS & ADDITIONAL |
| | ENGINEERING IF REQUIRED. TAKE INTO |
| | CONSIDERATION THE EDGE DISTANCE FOR |
| | STORM SHUTTERS AND GLASS SEPARATION |
| | REQUIRED.SEC. 104.2.1.2 CITY AMEND- |
| | MENTS TO FBC 2001. |