| Date |
Text |
| 2002-07-03 00:00:00 | CHECKLIST: |
| | 1-NEED RECORDED NOTICE OF COMMENCEMENT. |
| | 2-REVISE ATTIC ACCESS SIZE ON KEY NOTE |
| | #7. SEE SEC. 2309.6 FBC 2001. 36"MIN. |
| | 3-CLARIFY SIZE OF EGRESS WINDOWS. 34SH |
| | WINDOW DON'T PROVIDE 24" MIN. CLEAR |
| | HEIGHT OPENING. ARE THESE CUSTOM MADE |
| | WINDOWS?. SECTION 1005.4.4 FBC 2001. |
| | 4-CLARIFY STAIRS RATIO. SEE SHEET A-5. |
| | **NOTE: SEE OTHER COMMENTS ON PLANS AND |
| | BRING BACK REVIEWED SET. |
| | 5-SPECIFY FIREBLOCKING MATERIALS AND |
| | LOCATION AT STAIRS. SEC. 2305.1.4 FBC |
| | 6-SPECIFY DRAFSTOPPING LOCATION AND |
| | MATERIAL AT 2ND FL FRAMING PLAN. |
| | SEC. 2305.2.2 FBC 2001. |
| | 7-SPECIFY FIRECUTS AT MASONRY WALL AS |
| | REQUIRED BY SEC. 2305.4 FBC 2001. |
| | 8-PROVIDE SOIL TEST REPORT. |
| | 9-STORM SHUTTERS: |
| | A)PROVIDE COMPLETE INSTALLATION SCHEDULE |
| | AND KEY PLAN. SEE CITY SAMPLE. |
| | B)CLEARLY INDICATE ON DRAWINGS SPECIFIC |
| | MOUNTING CONDITIONS & ANCHOR TYPE AND |
| | SPACING TO BE USED ACCORDING TO THE |
| | MEAN ROOF HEIGHT, DESIGN PRESSURES, |
| | EDGE DISTANCE, PANEL SPAN, CONNECTION |
| | TYPE AND STRUCTURE TO BE ATTACHED TO |
| | (CONCRETE BLOCK OR CONCRETE) |
| | 10-PROVIDE PRODUCT APPROVAL FOR: |
| | A)DOUBLE ENTRY DOORS AS SHOWN ON PLANS. |
| | B)COMPLETE PAN AMERICAN WINDOW MULLION |
| | PRODUCT APPROVAL. |
| | C)ARCHED WINDOW NEED LEGIBLE DRAWINGS. |
| | AND SEE SIZES SHOWN ON PLANS. |
| | D)SINGLE HUNG WINDOWS PRODUCT APPROVAL |
| | IS NOT GOOD. FIRST PAGE DOESN'T MATCH |
| | THE REST OF PRODUCT APPROVAL. |
| | 11-PROVIDE UPDATED ORIGINAL LETTER FOR |
| | MASONRY USED ADDRESSED TO THE CITY OF |
| | W.P.B. AND THE CONTRACTOR AND SPECIFY |
| | THE PROJECT. |
| | 12-PROVIDE 2X STRUCTURAL BUCK DETAIL FOR |
| | FIXED WINDOWS AS REQUIRED ON THE |
| | SUBMITTED PRODUCT APPROVALS. |
| | 13-SHEET C-1: LOAD CALCULATIONS IS |
| | MISSING THE INTERNAL PRESSURE |
| | COEFFICIENT AS REQUIRED ON SECTION |
| | 1606.1.7 FBC 2001. |
| | 14-PROVIDE COMPLETE GABLE END DETAIL. |
| | SEE SECTION 2117.1.1 FOR CONTINUITY OF |
| | GABLE END WALL. |