| Plan Review Notes For Permit 02060381 |
| Permit Number |
02060381 |
|
| Review Stop |
B |
| Sequence Number |
80 |
|
| Notes |
| Date |
Text |
| 2004-11-13 00:00:00 | ****CORRECTIONS**** | | | REVISION TO BALCONY RAILING CONNECTION | | | PREPARED BY GW VARMAAS, PE | | | | | | 1.)SUBMITTALS ARE TO BE REVIEWED BY | | | THE DESIGNER OF RECORD. | | | | | | 2.)THE LANGUAGE ON THE LETTER REFERS | | | TO MASONRY WALL; ALLOWABLE LOADS | | | PROVIDED BY HILTI ARE FOR CONCRETE. | | | CLARIFY. | | | | | | 3.)THE DESIGN LOAD IS TO CONFORM TO | | | FBC1608.2.2.1 THROUGH 1608.2.2.4. | | | PROVIDE CALCS. | | | | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | | | | |
|