| 2004-04-12 00:00:00 | PRODUCT APPROVAL SUBMITTAL |
| | ***CORRECTIONS**** |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | [email protected] |
| | |
| | 1.)THE NOA IS NO LONGER IN THE |
| | PACKAGE THAT WAS PREVIOUSLY SUBMITTED |
| | FOR THE MECHANICAL ROOF.ARE YOU USING |
| | THE GUTTER ROOF PRODUCT AT THE |
| | MECHANICAL ROOF?IT IS MARKED GUTTER |
| | ROOF. |
| | |
| | 2.)A REQUEST WAS MADE FOR THE ORIGINAL |
| | SIGNED AND SEALED COVER LETTER AND TEST |
| | REPORT, SEE PREVIOUS LIST #3.THIS |
| | IS NO LONGER IN THE PACKAGE, ONLY |
| | PRODUCT DATA. |
| | |
| | 3.)REGARDING SERIES 35H (MD) |
| | STOREFRONT DOOR, STEELCRAFT DOORS, |
| | SERIES 800 SERVICE DOOR, SERIES 2000 SGD |
| | THE ZONE 5 PRESSURES EXCEED PRODUCT |
| | LIMITATIONS.ARE THESE TO BE INSTALLED |
| | IN ZONE 4 ONLY?WHAT WILL BE USED IN |
| | ZONE 5? |
| | |
| | 4.)THE STEELCRAFT DOOR IS TO BE |
| | TESTED TO ASTM E330-84, FBC35.PROVIDE |
| | A SITE SPECIFIC OR SUBMIT A TEST REPORT |
| | THAT COMPLIES WITH FBC.ALSO SEE |
| | PREVIOUS NOTE IN REGARDS TO THE |
| | PRESSURES. |
| | |
| | CC:DON NEELY |
| 2004-03-23 00:00:00 | ****CORRECTIONS**** |
| | PRODUCT APPROVAL SUBMITTAL |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | [email protected] |
| | |
| | 1.)NOA 030421.04, SIX STORY GUTTER |
| | ROOFS - MAX DESIGN PRESSURE IS 97.5, |
| | DESIGN PRESSURE FOR SIX STORY ROOF |
| | IS 146.2.SEE GENERAL LIMITATION #9. |
| | |
| | 2.)NOA 030212.06, THREE STORY |
| | MECHANICAL ROOF - MAX DESIGN PRESSURE IS |
| | -75, DESIGN PRESSURE FOR THREE STORY IN |
| | ZONE 2 IS 88.3.ENHANCED FASTENING, |
| | RATIONAL ANALYSIS OR EXTRAPOLATION |
| | IS TO BE DONE BY THE DESIGNER OF |
| | RECORD.SEE GENERAL LIMITATION #7. |
| | |
| | 3.)JOHNS MANVILLE MODIFIED BITUMEN |
| | TEST REPORT - SUPPLY AN ORIGINAL |
| | SIGNED AND SEALED COVER LETTER FROM |
| | ATLANTIC CARRIBEAN. (FOR ONE AND THREE |
| | STORY ROOFS) |
| | |
| | THE FOLLOWING ROOF PRODUCT APPROVAL |
| | SUBMITTALS ARE APPROVED CONDITIONALLY |
| | SUBJECT TO REVIEW BY DESIGNERS OF |
| | RECORD AS PER COMMENT ON MODIFIED |
| | BITUMEN ROOFING SHOP DRAWINGS: |
| | ULTRAGUARD PVC-LIGHTWEIGHT CONCRETE DE |
| | BASE SHEET ATTACHMENT CALCS, 1 STORY |
| | BASE SHEET ATTACHMENT CALCS, 3 STORY |
| | ALTUSA S |
| | POLYFOAM |
| | TILE SPECS, SYSTEM B |
| | TILE UNDERLAYMENT FASTENER SPACING |
| | TILE ATTACHMENT CALCS |
| | |
| | 4.)AS PER CONVERSATION WITH BOB |
| | LUTHER, WINDOW DESIGN PRESSURES WERE |
| | NOT ON THE PLAN AND WERE PROVIDED AS |
| | A SEPARATE SUBMITTAL.PROVIDE A COPY |
| | FROM THE ENGINEER SO THAT THE OTHER |
| | PRODUCTS SUBMITTED CAN BE REVIEWED. |
| | |
| | |
| | ROOF SUBMITTAL #07A-05-07552-0 |
| | SIX STORY MODIFIED ROOF DATA |
| | |
| | ROOF SUBMITTAL #07A-04-07522-0 |
| | 1 & 3 STORY MODIFIED ROOF DATA |
| | |
| | PLEASE RESUBMIT AFTER APPROVAL OF |
| | SYSTEM (TEST REPORTS) BY DESIGNER OF |
| | RECORD. |
| | |
| | |
| | |
| | |
| | |
| | CC:DON NEELY |