| 2003-01-27 00:00:00 | CHECKLIST FOR PROVISO SUBMITTAL: |
| | 1-ENGINEERING CALCULATIONS SHOW THAT |
| | WOOD COLUMNS (P1) ARE NOT STRUCTURALLY |
| | ADEQUATE. SHEET S-1 SHOWS WOOD COLUMN |
| | P1 AT DEN AREA. CLARIFY AND REVISE AS |
| | REQUIRED AND PROVIDE CERTIFICATION |
| | THAT STEEL COLUMN WAS INSTALLED. |
| | SEC. 104.2.1.2 CITY AMENDMENTS TO FBC. |
| | 2-PROVIDE SOIL TEST REPORT. THERE'S NONE |
| | SUBMITTED FOR THE CITY FILES. |
| | 3-STORM SHUTTERS: A)PROVIDE COMPLETE |
| | SBCCI PRODUCT APPROVAL REPORT #2229. |
| | B)CLEARLY MARK ON DRAWINGS SPECIFIC |
| | MOUNTING CONDITIONS AND ANCHOR TYPE & |
| | SPACING TO BE USED ACCORDING TO THE |
| | MEAN ROOF HEIGHT, DESIGN PRESSURES, |
| | EDGE DISTANCE, PANEL SPAN, CONNECTION |
| | TYPE AND STRUCTURE TO BE ATTACHED TO. |
| | C)CHECK DESIGN PRESSURES SPECIFIED ON |
| | PLANS AND THOSE SPECIFIED ON INSTALLA- |
| | TION SCHEDULE. |
| | D)PROVIDE INSTALLATION SCHEDULE AND KEY |
| | PLAN THAT MATCH ACTUAL PLANS SUBMITTED |
| | |
| | 4-SINGLE HUNG WINDOWS PRODUCT APPROVAL |
| | IS EXPIRED. |
| | 5-ENTRY DOOR PRODUCT APPROVAL NEED FRONT |
| | PAGE TO HAVE DADE COUNTY LOGO AND THE |
| | DRAWINGS STAMPED WITH THE RENEWAL # AS |
| | REQUIRED BY DADE COUNTY. |