2002-07-10 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1) SHT E-1.0R TUB AND SHOWER ARE NOT
 VENTED IN MASTER BATH. 2ND NOTICE. THE
 WET VENT SHALL BE CONSIDERED THE VENT
 FOR THE FIXTURES AND SHALL ENTEND FROM
 THE CONNECTION OF THE DRY VENT ALONG THE
 DIRECTION OF THE FLOW IN THE DRAIN PIPE
 TO THE MOST DOWNSTREAM FIXTURE DRAIN
 CONNECTION TO THE HORIZONTAL BRANCH
 DRAIN. SECTION 909.1
 2) SHT E-1.0R PLUMBING NOTES #7 CHANGE
 TO READ WATER HAMMER ARRESTORS, NOT
 WATER CHAMBERS ARRESTORS.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377