Plan Review Notes
Plan Review Notes For Permit 02050710
Permit Number 02050710
Review Stop R
Sequence Number 1
Notes
Date Text
2002-06-13 00:00:00BUILDING DENIED
  
 1) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 2) FBC* 104.2.5SITE SURVEY.A SIGNED
 AND SEALED SURVEY DRAWING PREPARED BY A
 QUALIFIED SURVEYOR IS REQUIRED.
  
 3) SURVEY IS NEEDED IN ORDER TO REVIEW
 PLAN FOR COMPLIANCE WITH FBC TABLE 600
 FOR PERCENT OF WALL AREA ALLOWED AS
 OPENINGS.
  
 4) PLEASE CHANGE NOTE #2 ON A1 TO REFER
 TO 2001 FLORIDA BUILDING CODE.
  
 5) PLEASE CHANGE NOTE #1 ON S5 UNDER
 SAFEGUARDS TO REFERENCE THE FBC.
  
 6) PLEASE INDICATE ON SHEET A4 THAT THE
 STUCCO APPLIED VERTICALLY ON METAL LATHE
 OVER A SOLID BASE IS REQUIRED TO BE 7/8"
 THICK PER FBC SEC. 2504.2 AND ASTM C-926
  
 7) PLEASE INDICATE ON THE PLANS THAT
 ADEQUATE SUBSTRATE WILL BE PROVIDED FOR
 THE ATTACHMENT OF THE STORM PANELS.
  
 8) PLEASE CORRECT DETAIL 1 ON S3, WHICH
 INDICATES 3/16" HOLES FOR THE 3/4" BOLTS
  
 9) PLEASE CORRECT THE FOLLOWING NOTES ON
 ON SHEET A5:
 - NOTE #5 UNDER ROOF SHEATHING REFERS TO
 SBC
 - NOTE #1 UNDER REINFORCED CONCRETE
 REFERS TO THE SBC. NOTE #7 REFERS TO
 ASTM A-185 AND IT SHOULD BE ASTM A-185.
 THE NOTES STATE THAT WWF SHOULD BE
 LIFTED DURING CONCRETE PLACEMENT, THE
 FBC SEC. 1909.3 REQUIRES THE WELDED WIRE
 FABRIC TO BE SUPPORTED.
  
 10)PLEASE CORRECT THE DESIGN INFORMATION
 GIVEN ON SHEET S1. THE EXPOSURE
 CATEGORY FOR LARKSPUR LANDING IS B, THE
 IMPORTANCE FACTOR IS 1.00, THE ASCE
 TABLE FOR DETERMINING THE IMPORTANCE
 FACTOR IS 6-1 IN ASCE7-98. PLEASE
 INDICATE THE INTERNAL PRESSURE
 COEFFICIENT ( + OR - .18 FOR ENCLOSED).
 THE 2001 FBC SECTION 1606.1.7
 REQUIRES THE FOLLOWING INFORMATION TO BE
 SHOWN ON THE CONSTRUCTION DRAWINGS:
 - BASIC WIND SPEED, MPH.
 - WIND IMPORTANCE FACTOR(1) AND BUILDING
 CATEGORY.
 - WIND EXPOSURE- IF MORE THAN ONE WIND
 EXPOSURE IS USED THE WIND EXPOSURE AND
 APPLICABLE WIND DIRECTION SHALL BE
 INDICATED.
 - THE APPLICABLE INTERNAL PRESSURE
 COEFFICIENT
 - COMPONENTS AND CLADDING. THE DESIGN
 WIND PRESSURES IN TERMS OF PSF, TO BE
 USED FOR THE DESIGN OF EXTERIOR
 COMPONENT AND CLADDING MATERIALS NOT
 SPECIFICALLY DESIGNED BY THE REGISTERED
 DESIGN PROFESSIONAL.
  
 11) THE CALCULATED WINDLOAD PRESSURES
 FOR THE SINGLE HUNG WINDOWS AND SLIDING
 GLASS DOOR GIVEN ON THE PLANS EXCEEDS
 THE DESIGN PRESSURES LISTED IN THE SBCCI
 PRODUCT APPROVAL FOR KDI WINDOWS AND THE
 COMPARATIVE ANALYSIS SUBMITTED IS NOT A
 VALID DOCUMENT.
  
 12) PROVIDE (2) CURRENT AND COMPLETE
 COPIES OF SBCCI OR METRO-DADE PRODUCT
 APPROVALS FOR:
 - STRUCTURAL MULLIONS
 - ROOF TILE ; THE PRODUCT APPROVALS FOR
 THE ENTEGRA ROOF TILE EXPIRED PRIOR TO
 DATE OF SUBMITTAL
  
 13) PROVIDE KEY PLAN AND INSTALLATION
 SCHEDULE FOR THESE PLANS (MODEL E).
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202