| Plan Review Notes For Permit 02050589 |
| Permit Number |
02050589 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2002-06-11 00:00:00 | BUILDING DENIED | | | | | | 1) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2) PROVIDE A DETAILED LIST OF ALL THE | | | WORK THAT IS TO BE DONE. | | | | | | 3) INDICATE WHICH DOORS/WINDOWS ARE TO | | | BE REPLACED. IF NEW WINDOWS OR DOORS ARE | | | BEING ADDED, YOU MUST SHOW COMPLIANCE | | | WITH 2001 FBC TABLE 600 REQUIREMENTS FOR | | | THE PERCENT OF WALL OPENINGS ALLOWED | | | BASED ON THE DISTANCE TO THE PROPERTY | | | LINE. | | | | | | 4) IF THE WINDOWS BEING REPLACED ARE IN | | | A SLEEPING ROOM THE NEW WINDOWS MUST | | | COMPLY WITH FBC SEC. 1005.4, EMERGENCY | | | EGRESS. | | | | | | 5) PROVIDE A KEY PLAN AND INSTALLATION | | | SCHEDULE FOR THE STORM PANELS, IN | | | ADDITION TO THE PRODUCT APPROVAL. SEE | | | ATTACHED. | | | | | | 6) PLEASE CLARIFY THE NOTE REFERING TO | | | THE EXTERIOR FINISH GRADE AND HOW YOU | | | WILL ACHIEVE COMPLIANCE WITH THE CODE. | | | FBC SEC. 1403.1.6 REQUIRES 6" OF | | | CLEARANCE BETWEEN EXTERIOR WALL COVERING | | | AND FINAL EARTH GRADE. 1804.1.7 REQUIRES | | | THE FINISH GRADE TO BE SLOPED AWAY FROM | | | THE FOUNDATION. | | | | | | 7) A PRE-INSPECTION WILL BE REQUIRED | | | PRIOR TO THE PERMIT BEING ISSUED. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)659-8096 EXT.8202 |
|