Plan Review Notes
Plan Review Notes For Permit 02050585
Permit Number 02050585
Review Stop B
Sequence Number 2
Notes
Date Text
2002-09-25 00:00:00BUILDING PLAN REVIEW
 PERMIT: 02050585
 ADD: 941 44TH ST
 CONT: O/B DOUGLAS, ESTELLA
 TEL: (561)848-0633
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 *****PROVISO*****
  
 MISSING PRODUCT APPROVALS ARE TO BE
 SUBMITTED BEFORE BUCK INSPECTION :
 A) MULLIONS
 B) ROOF ASSEMBLIES
 1707.4.5.1 MULLIONS OCCURRING
 BETWEEN INDIVIDUAL WINDOW AND GLASS
 DOOR ASSEMBLIES. TESTING REPORTS ARE
 REQUIRED BY AN APPROVED TESTING
 LABORATORY OR BE ENGINEERED.
 1707.4.5.2 MULLIONS SHALL BE DESIGN-
 ED TO TRANSFER THE DESIGN PRESSURE LOADS
 APPLIED BY THE WINDOW OR DOOR ASSEMBLIES
 TO THE ROUGH OPENING SUBTRATE.
 BUILDING PLAN REVIEW
 JIM WITMER
 (561)659-8096 X8412