Text |
| 2002-05-14 00:00:00 | ~~~~~~~~~~~~~~~~~~PROVISO!~~~~~~~~~~~~~~ | | | | | | | | | | | | 1} PLEASE NOTE ALL OUTLETS SERVING | | | KITCHEN COUNTERSPACE AS GFI/GFI | | | PROTECTED PER 210-8-A-6.AND COMPLY | | | WITH 210-52(1 THROUGH 5). | | | | | | 2} PLEASE LIST THE REQ'D BATH(S) | | | CIRCUIT(S). PER 210-11-C-3 | | | MUST BE 20A AND #12AWG. | | | | | | 3} PLEASE LIST THE REQ'D ARC | | | FAULT PROTECTED CIRCUITS ON PANEL | | | SCHEDULE. PER 210-12 | | | | | | 4} PLEASE NOTE FRONT AND REAR | | | RECEPTS REQ`D PER 210-52E | | | | | | 5} PLEASE NOTE MISSING OUTLET FOR | | | A/C EQUIPMENT. PER 210-63 AND/OR SECTION | | | 306 OF THE MECHANICAL CODE.LIGHT PER | | | 210-70(A)(3). | | | | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/659-8096 EXT. 8392 |
|